MPPT017 Design of Switching Magnet for 20-MeV Beamlines at PEFP 1575
 
  • H.S. Suh, H.S. Han, S.-H. Jeong, Y.G. Jung, H.-S. Kang, H.-G. Lee, K.-H. Park, C. K. Ryu
    PAL, Pohang, Kyungbuk
 
  Funding: Ministry of Science and Technology.

The PEFP(Proton Engineering Frontier Project) proton linac is designed to have two proton beam extraction lines at the 20-MeV and 100-MeV end. The 20-MeV extraction line is branched out into 5 beamlines by using the switching magnet. The magnet bends the proton beam by +20, +10, 0, -10, -20 degrees, respectively, and has an AC frequency of 5 Hz with a programmable ac power supply. It employs an H-shape, 0.45 T magnetic field, 0.5 m effective magnet length, 30x5 cm bore aperture. The pole shape is optimized for the field levels. Laminated steel of 0.5 mm is enough to suppress the eddy current effect in the yoke. This paper presents the magnet specification and primary design.

 
WPAE016 Development of a Precision Amplifier for the Detector 1514
 
  • K.-H. Park, C.W. Chung, S.-M. Hong, S.-H. Jeong, Y.G. Jung, D.E. Kim, H.-S. Lee, W.W. Lee
    PAL, Pohang, Kyungbuk
  • B.-K. Kang
    POSTECH, Pohang, Kyungbuk
 
  A high gain trans-resistance amplfier has been developed for measuring the intensity of synchrotron radiation at Pohang Light Source(PLS). This amplifier built with discrete elements and operational amplifiers.It had the capability of measuring range from 1pA to 1 uA with good linearity. A microprocessor was also installed to interface the amplifier with the computer, and controlled the other sub-circuits. The various characteristics of amplifier such as linearity, sensitivity,stability, etc. have been investigated, and its experimental results carried out at the beam line are presented in this paper.  
WPAE060 Programmable Power Supply for AC Switching Magnet of Proton Accelerator 3508
 
  • S.-H. Jeong, H.S. Han, Y.G. Jung, H.-S. Kang, H.-G. Lee, K.-H. Park, C. K. Ryu, H.S. Suh
    PAL, Pohang, Kyungbuk
  • H.H. Lee
    UU, Gyeongju
 
  Funding: Ministry of Science and Technology.

The 100-MeV PEFP proton linac has two proton beam extraction lines for user’ experiment. Each extraction line has 5 beamlines and has 5 Hz operating frequency. An AC switching magnet is used to distribute the proton beam to the 5 beamlines, An AC switching magnet is powered by PWM-controlled bipolar switching-mode converters. This converter is designed to operate at ±350A, 5 Hz programmable step output. The power supply is employed IGBT module and has controlled by a DSP (Digital Signal Process). This paper describes the design and test results of the power supply.