A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Ishii, I.

Paper Title Page
RPAT053 Movement of BPMs Due to Thermal Stress in KEKB 3253
 
  • M. Tejima, A. Arinaga, H. Fukuma, S. Hiramatsu, T. Ieiri, I. Ishii, M. Tobiyama
    KEK, Ibaraki
 
  Movement of Beam Position Monitors (BPM) due to thermal stress in high beam current operation is observed in KEKB. For high luminosity operation of KEKB, the beam current as high as 1.6A is accumulated in the positron ring and a precise control of the beam orbit based on the BPM system is required. Though the every BPM chamber is fixed firmly on a support of each quadrupole magnet, the BPM chamber moves several hundred microns from the setting position depending on the beam current due to beam pipe heating by strong synchrotron light irradiation. Such movement introduces an unavoidable offset error in the BPM measurement, and is a serious problem not only for KEKB but also for the next generation of B-factory operated with extremely high beam current. We report the measurement of the movement by distance sensors and an attempt to correct the BPM offset error in real-time operation.