RPPE014 Temperature Regulation of the Accelerating Section in CANDLE Linac 1416
 
  • S. Tunyan, G.A. Amatuni, B. Grigoryan
    CANDLE, Yerevan
 
  The temperature of the CANDLE S-Band Linac high-power RF components will be regulated by stand-alone closed loop (SACL) water system. The RF components are made of oxygen-free high conductivity copper and respond quickly to temperature changes. Temperature stabilization better than ± 0.1 C is required to achieve a good RF phase and energy stability. The temperature regulation and control philosophy along with the simulation results are discussed.