Ford, R.

Paper Title Page
RPAT044 Segmented Foil SEM Grids at Fermilab 2821
 
  • S.E. Kopp, D. Indurthy, Z. Pavlovich, M. Proga, R.M. Zwaska
    The University of Texas at Austin, Austin, Texas
  • B.B. Baller, S.C. Childress, R. Ford, D. Harris, C.L.K. Kendziora, C.D. Moore, G. R. Tassotto
    Fermilab, Batavia, Illinois
 
  Segmented Secondary Emission Monitors (SEM's) will be used to monitor the extracted 120 GeV proton beam for the NuMI facility at Fermilab. The SEM's are constructed from 5 micrometer thick Ti foils. The chambers have 10 cm beam aperture, and the foils are designed to result in 4·10-6 fractional beam loss when inserted in the beam. The foil strips have dynamic tensioning to withstand the heating from the 400kW proton beam. Results from prototype beam tests as well as from commissioning in the NuMI line will be presented.