The beam parameters were investigated using an azimuth-sectionalized 8-channel Faraday cup and a 12-channel computer-aided measuring system. The magnetron diode had a cathode (40 mm in diameter) and a 15 mm anode-cathode gap. At a cathode voltage amplitude of 50 kV and a cathode magnetic field of ~1200 Oe, the diode generates a tubular electron beam with an outer diameter of 50 mm, an inner diameter of 44 mm, a beam current of ~50 A. The short time instability of the total beam current, and of the current from each of eight segments of the Faraday cup was estimated to be ~2
3%, and long time instability (3 hours) was 5…7 %. Azimuthal distribution of beam current was investigated versus the amplitude, distribution and direction of the magnetic field. At a cathode magnetic field of 1200 Oe, that falls off inhomogeneity in the vicinity of the Faraday cup down to ~800 Oe, the azimuthal beam current distribution has a ± (3
5)%. As the magnetic field strength increases up to ~1700 Oe in the region of beam emergence from the gun and the Faraday cup, the azimuthal inhomogeneity of the beam current increases up to ± (100
150)%.
|
|