TUPYP017 | Design and Test of Precision Mechanics for High Energy Resolution Monochromator at the HEPS | 51 |
|
||
A monochromator stands as a typical representative of optical component within synchrotron radiation light sources. High resolution monochromators (HRMs), which incorporate precision positioning, stability control, and various other technologies, are a crucial subclass within this category. The next generation of photon sources imposes higher performance standards upon these HRMs. In this new design framework, the primary focus is on innovating precision motion components. Rigorous analysis and experimentation have confirmed the effectiveness of this design. This structural model provides valuable reference for developing other precision adjustment mechanisms within the realm of synchrotron radiation. | ||
Poster TUPYP017 [3.641 MB] | ||
DOI • | reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-TUPYP017 | |
About • | Received ※ 01 November 2023 — Revised ※ 03 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 04 February 2024 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPYP018 | Design and Improvements of a Cryo-Cooled Horizontal Diffracting Double Crystal Monochromator for HEPS | 55 |
|
||
Horizontal diffracting double crystal monochromator(HDCM) are usually used in a 4th generation light source beamline due to the larger source size in the horizontal direction. This paper introduces the mechanical design and optimization of a HDCM for Low-dimension Structure Probe Beamline of HEPS. In order to achieve the high stability requirement of 50nrad RMS, the structural design is optimized and modal improved through FEA. In order to meet the requirement of a total crystal slope error below 0.3¿rad, FEA optimizations of the clamping for first and second crystal are carried out. The vacuum chamber is optimized to become more compact, improving the maintainability. Fabrication of the HDCM is under way. The results show that the design is capable of guarantee the required surface slope error, stability, and adjustment requirements. | ||
Poster TUPYP018 [1.172 MB] | ||
DOI • | reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-TUPYP018 | |
About • | Received ※ 02 November 2023 — Revised ※ 03 November 2023 — Accepted ※ 09 November 2023 — Issued ※ 11 May 2024 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPPP050 | Quick scanning Channel-Cut crystal monochromator for millisecond time resolution EXAFS at HEPS | 229 |
|
||
The design and capabilities of a Quick scanning Channel-Cut monochromator (QCCM) for HEPS are presented. The quick scan and step scan are realized by a torque motor directly driven Bragg axis, controlled by a servo controller. This design allows easy and remote control of the oscillation frequency and angular range, providing comprehensive control of QXAFS measure-ments. The cryogenically cooled Si (311) and Si(111) crystals, which extends the energy range from 4.8 keV-45 keV. The dynamic analysis verifies the rationality of the mechanical structure design. The device was fabri-cated and tested, results show an oscillation frequency up to 50Hz with a range of 0.8°, and a resolution of 0.2 arcsecond in step scan mode. This device demonstrates the feasibility of large range quick scan and step scan by a single servo control system.
Quick scanning Channel-Cut crystal monochromator |
||
DOI • | reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-WEPPP050 | |
About • | Received ※ 02 November 2023 — Revised ※ 05 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 08 January 2024 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THOBM03 |
Progress and Core Technologies Development of Monochromators for HEPS | |
|
||
HEPS is the first low emittance 4th generation light source in China, as monochromators are often limiting the performance of beamlines, many challenges are faced to preserve the quality of the beam. In order to meet the stringent and versatile requirements of 12 in house developed monochromators for different beamlines, several core technologies have been studied and developed. Stability considerations, vibration measurement system and methods are introduced, stability below 10 nrad RMS are measured for operation conditions by laser interferometers. Thermal resistance study at low temperature was carried out, enabling more accurate FEA of cooling. Clamping deformation of crystals at low temperature are experimentally studied, slope errors below 0.1 microradian RMS are measured. Design and test results on different types of monochromators will also be presented. Results show that the in house developed monochromators are able to meet the requirements of HEPS beamlines. | ||
Slides THOBM03 [8.445 MB] | ||
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPPP023 | Design and Test of a New Crystal Assembly for a Double Crystal Monochromator | 313 |
|
||
Vertical diffraction monochromator is a typical optical device in synchrotron radiation device. Its main requirements and characteristics are high Angle accuracy and stability. Due to the high requirements of new light sources, high precision and high stability have become a common difficulty. This paper mainly introduces the design and test of an internal crystal module of HDCM. There are two main parts: the first crystal and the second crystal. The first crystal assembly includes crystal cooling and clamping, using microchannel edge cooling and flat plate clamping schemes. The second crystal component, through the motor to the top, drives the flexible hinge, and then realizes the rotation of the crystal. At the same time, the Angle monitoring system is designed. The design scheme is verified by processing. The shape of the clamping surface of a crystal component meets the requirements of use. The motion test of the two crystal components is carried out in the atmosphere, vacuum and low temperature vacuum environment, and the results are much higher than the required parameters. And the whole stability is tested. It has high stability. | ||
DOI • | reference for this paper ※ doi:10.18429/JACoW-MEDSI2023-THPPP023 | |
About • | Received ※ 02 November 2023 — Revised ※ 05 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 19 December 2023 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |