Paper |
Title |
Page |
WEOAM02 |
A Vacuum Aspirated Cryo Cooling System (VACCS) |
121 |
|
- G.M.A. Duller, D.L. Magrath, M. Nagy, B. Olafsson
DLS, Oxfordshire, United Kingdom
|
|
|
The use of liquid nitrogen for cooling of synchrotron equipment is widespread. The cryogenic sub-coolers commonly employed come with some significant drawbacks such as cost, complexity, stiffness of distribution lines, and vibration induced by pressure variations. The typical sub-cooler is capable of handling 2-3kW of absorbed power whilst many optics require no more than 50-150W of cooling. We present a Vacuum Aspirated Cryo-cooling System (VACCS) which overcomes many of these disadvantages and which allows cryo-cooling to be implemented more widely. The VACCS system uses a vacuum, generated with no moving parts, to draw LN2 through a heat exchanger. Thus the system does not have to be pressure rated. We describe our designs for highly flexible distribution lines. A simple control system offers variable temperature at the heat exchanger by varying the flowrate of LN2. A system is installed at Diamond which allows the independent control of three zones. A test rig has demonstrated cooling capacity in excess of 100W for a monochromator crystal assembly and controlled temperatures -194¿-120C.
|
|
|
Slides WEOAM02 [21.578 MB]
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-MEDSI2023-WEOAM02
|
|
About • |
Received ※ 31 October 2023 — Revised ※ 27 November 2023 — Accepted ※ 08 November 2023 — Issued ※ 08 January 2024 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|