Recently we did bunker tests for FRIB first cryomodule (CM-1) and second one (CM-2) which houses 0.085 QWRs and solenoid packages. Their performances were successfully validated in the full configuration. This paper reports the solenoid package tests results.
 
poster icon Poster TUPLR067 [4.899 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-TUPLR067  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPRC024 Polarity Check of the FRIB Cryomodule Solenoids by Measuring Leakage Magnetic Field 821
 
  • H. Ao, D. Luo, F. Marti, K. Saito, S. Shanab
    FRIB, East Lansing, USA
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE SC0000661.
We observed the outside magnetic field of the first β=0.085 production cryomodule while a solenoid and steering dipoles are under operation. This measurement aims to check the polarity on these magnets after the final installation in the accelerating tunnel. This paper also shows the residual magnetic field variation through the degaussing process of these magnets.
 