Paper | Title | Page |
---|---|---|
MOPRC029 | Experiment of Plasma Discharge on HWR Cavity for In-Situ Surface Cleaning Study | 133 |
SPWR008 | use link to see paper's listing under its alternate paper code | |
|
||
Hydrocarbons, which migrate from the vacuum bumps system, will absorb on the cavity surface after periods of operation. The contaminants can reduce the surface electron work function to enhance the field emission effect and restrict the cavity accelerating gradient. The room temperature in-situ plasma surface processing to clean the hydrocarbon contaminants can act as a convenient and efficient technology for the accelerator on line performance recovery. For better control of the discharge inside the cavity, the experiment works on a single HWR cavity aims to research the ignition between the swarm parameters (gas flow, pressure, forward power). | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-MOPRC029 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
MOPLR053 | Operating Status of Injector II RFQ for C-ADS Project | 254 |
|
||
The Radio Frequency Quadrupole system has been designed and constructed for C-ADS (Chinese Accelerator Driven System) Injector II in Institute of Modern Physics (IMP), Chinese Academy of Sciences, which has been running for more than one year until now. It is a quadrilateral four-vane resonator with two equal couplers operating in CW mode. In the paper, RF system upgrade will be presented in detail,especially the two-port configuration was introduced and the conditioning based on two new sets of solid-state amplifier instead of the original tetrodes power source due to system hardware upgrade are described in the paper.
RFQ, solid-state amplifier, two-port configuration, coupler |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-MOPLR053 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
MOPLR060 | CIADS Normal Temperature Front-End Design | 267 |
SPWR036 | use link to see paper's listing under its alternate paper code | |
|
||
The design and construction with several tens of megawatts superconducting accelerator is the developing direction in the further. The superconducting section follows the RFQ and MEBT, which needs good enough beam quality. The normal temperature front ends are redesigned for China Initiative ADS. The LEBT transports a 35KeV, 10mA DC proton beam to the RFQ, after the RFQ acceleration the MEBT transports a 2.1MeV 10mA CW proton beam to the superconducting DTL. The "Point Source" is proposed in the beam scrape application during the LEBT section to get the ideal transverse beam parameters. To get the ideal longitudinal beam parameters, the new RFQ is designed with little emittance. Collimators are installed in the new MEBT to scrape the outer sphere beams which may turn to halo. Details of the beam dynamics simulations will be given. | ||
![]() |
Poster MOPLR060 [1.109 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-MOPLR060 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TU1A04 |
Commissioning of the Lanzhou ADS Front-end | |
|
||
Report on the construction and beam commissioning of the front-end up to the first or second cryomodule at IMP Lanzhou. | ||
![]() |
Slides TU1A04 [8.316 MB] | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPLR066 | High Current Beam Injector for Cancer Therapy | 604 |
|
||
A hybrid single cavity (HSC) linac, which is formed by combining a radio frequency quadrupole (RFQ) and a drift tube (DT) structure into one interdigital-H (IH) cavity, is fabricated and assembled as a proof of principle injector for cancer therapy synchrotron, based on the culmination of several years of research. The HSC linac adopts a direct plasma injection scheme (DPIS), which can inject a high intensity heavy ion beam produced by a laser ion source (LIS). The input beam current of the HSC is designed to be 20 mA C6+ ions. According to numerical simulations, the HSC linac can accelerate a 6-mA C6+ beam, which meets the requirement of the needed particle number for cancer therapy (108~9 ions/pulse). The HSC injector with the DPIS method makes the existing multi-turn injection system and stripping system unnecessary, and can also bring down the size of the beam pipe in existing synchrotron magnets, which could reduce the whole cost of synchrotron. The radio frequency (RF) measurements show excellent RF properties for the resonator, with a measured Q equal to 91% of the simulated value. A C6+ ion beam extracted from the LIS was used for the HSC commissioning. In beam testing, we found the measured beam parameters agreed with simulations. More details of the measurements and the results of the high power test are reported in this paper. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-TUPLR066 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPLR063 | RF Design of a Deuteron Beam RFQ | 996 |
SPWR020 | use link to see paper's listing under its alternate paper code | |
|
||
In a material irradiation facility in IMP, a RFQ is required for accelerating deuteron beam from 20 keV/u to 1.52 MeV/u. The structure design of the RFQ is drawing on the experience of the RFQ of Injector II of China ADS LINAC. Four-vane structure is adopted and the operation frequency is 162.5 MHz. Inter vane voltage is 65 kV and the Kilpatrick factor is 1.4. Π-mode stabilizing loops are used to move the dipole modes away from the working mode. Slug tuners are used to compensate for capacitance errors induced by machining. Cutbacks and end plate are modified to reach a reasonable field flatness. After the structure design and optimization, the simulation results of the cavity frequency is 162.459 MHz, the power loss is 109 kW. The multiphysics simulations are also performed to determine the frequency shift caused by the shift of the cooling water temperature. | ||
![]() |
Poster THPLR063 [0.971 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-THPLR063 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPLR064 | Design and Simulation of a High Intensity Heavy Ion RFQ Accelerator Injector | 999 |
SPWR019 | use link to see paper's listing under its alternate paper code | |
|
||
An 81.25 MHz continuous wave (CW) radio frequency quadrupole (RFQ) accelerator has been developed for Low Energy Accelerator Facility (LEAF) at the Institute of Modern Physics (IMP), the Chinese Academy of Science (CAS). In the CW operating mode, the proposed RFQ design adopted the conventional four-vane structure. The main design goals are providing the high shunt impendence with low power losses. In the electromagnetic (EM) design, the π-mode stabilizing loops (PISLs) were optimized to produce a good mode separation. The tuners were also designed and optimized to tune frequency and field flatness of the operating mode. The vane undercuts were optimized to provide a flat field along the RFQ cavity. Additionally, a full length model with modulations was set up for the final EM simulations. In this paper, detailed EM design of the LEAF-RFQ will be presented and discussed. Meanwhile, structure error analysis is also studied. | ||
![]() |
Poster THPLR064 [3.021 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2016-THPLR064 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |