Keyword: storage-ring
Paper Title Other Keywords Page
TUPLB09 Design and Beam Test of Six-electrode BPMs for Second-order Moment Measurement factory, electron, multipole, linac 464
 
  • K. Yanagida, H. Hanaki, S. Suzuki
    JASRI/SPring-8, Hyogo-ken, Japan
 
  In the SPring-8 linac, four-electrode beam position monitors (BPMs) have been utilized for the measurement of the transverse first-order moments, which correspond to the centroids of beam charge distributions. We have planed to measure the transverse second-order moments of beams to obtain information of beam optics and its energy deviations during the top-up beam injection without destruction of beams. Therefore, six-electrode BPMs with circular and quasi-ellipse cross-sections have been developed on the basis of a newly introduced theory. A low-noise signal processor for the six-electrode BPM has also been developed to perform fine measurement. We expected the following resolutions determined by the S/N ratio of the circuit; the first order moments (beam positions) > 1 μm, and the second order moments with a size > 110 μm. The first beam test was carried out using the six-electrode BPM with circular cross-section and the old signal processor. The measured sensitivities and resolutions of the second-order moments showed good agreement with the theory.  
slides icon Slides TUPLB09 [8.248 MB]  
 
TUPB079 Design and Beam Test of Six-Electrode BPMs for Second-Order Moment Measurement factory, electron, multipole, linac 654
 
  • K. Yanagida, H. Hanaki, S. Suzuki
    JASRI/SPring-8, Hyogo-ken, Japan
 
  In the SPring-8 linac, four-electrode beam position monitors (BPMs) have been utilized for the measurement of the transverse first-order moments, which correspond to the centroids of beam charge distributions. We have planed to measure the transverse second-order moments of beams to obtain information of beam optics and its energy deviations during the top-up beam injection without destruction of beams. Therefore, six-electrode BPMs with circular and quasi-ellipse cross-sections have been developed on the basis of a newly introduced theory. A low-noise signal processor for the six-electrode BPM has also been developed to perform fine measurement. We expected the following resolutions determined by the S/N ratio of the circuit; the first order moments (beam positions) >1 μm, and the second order moments with a size >110 μm. The first beam test was carried out using the six-electrode BPM with circular cross-section and the old signal processor. The measured sensitivities and resolutions of the second-order moments showed good agreement with the theory.