Author: Hayano, H.
Paper Title Page
MOPLB07 Non-destructive Inspections for SC Cavities 156
 
  • Y. Iwashita, Y. Fuwa, M. Hashida, K. Otani, S. Sakabe, S. Tokita, H. Tongu
    Kyoto ICR, Uji, Kyoto, Japan
  • H. Hayano, K. Watanabe, Y. Yamamoto
    KEK, Ibaraki, Japan
 
  Non-destructive Inspections play important roles to improve yield in production of high-performance SC Cavities. Starting from the high-resolution camera for inspection of the cavity inner surface, high resolution T-map, X-map and eddy current scanner have been developed. We are also investigating radiography to detect small voids inside the Nb EBW seam, where the target resolution is 0.1 mm. We are carrying out radiography tests with X-rays induced from an ultra short pulse intense laser. Recent progress will be presented.  
slides icon Slides MOPLB07 [5.810 MB]  
 
MOPB025 1ms Multi-bunch Electron Beam Acceleration by a Normal Conducting RF Gun and Superconducting Accelerator 228
 
  • M. Kuriki, S. Hosoda, H. Iijima
    HU/AdSM, Higashi-Hiroshima, Japan
  • H. Hayano, J. Urakawa, K. Watanabe
    KEK, Ibaraki, Japan
  • G. Isoyama, R. Kato, K. Kawase
    ISIR, Osaka, Japan
  • S. Kashiwagi
    Tohoku University, Research Center for Electron Photon Science, Sendai, Japan
  • A. Kuramoto
    Sokendai, Ibaraki, Japan
  • K. Sakaue
    RISE, Tokyo, Japan
 
  Funding: Quantum Beam Project by MEXT, Japan
We perform electron beam generation and acceleration of 1 ms long pulse and multi-bunch format at KEK-STF (Superconducting Test Facility). The 1 ms long pulse beam is generated by a normal conducting photo-cathode L-band RF gun. The beam is boosted up to 40 MeV by a super-conducting accelerator. Aim of STF is to establish the super-conducting accelerator technology for ILC (International Linear Collider). The facility is concurrently used to demonstrate high brightness X-ray generation by inverse laser Compton scattering supported by MEXT Quantum Beam project. The RF gun cavity has been fabricated by DESY-FNAL-KEK collaboration. After conditioning process, a stable operation of the cavity up to 4.0 MW RF input with 1 ms pulse was achieved by keeping low dark current. 1 ms pulse generation and acceleration has been confirmed in March 2012. Quasi-monochromatic X-ray generation experiment by Laser-Compton will be carried out at STF from the next coming July. We report the latest status of STF.
 
 
MOPB053 Non-destructive Inspections for SC Cavities 294
 
  • Y. Iwashita, Y. Fuwa, M. Hashida, K. Otani, S. Sakabe, S. Tokita, H. Tongu
    Kyoto ICR, Uji, Kyoto, Japan
  • H. Hayano, K. Watanabe, Y. Yamamoto
    KEK, Ibaraki, Japan
 
  Non-destructive Inspections play important roles to improve yield in production of high-performance SC Cavities. Starting from the high-resolution camera for inspection of the cavity inner surface, high resolution T-map, X-map and eddy current scanner have been developed. We are also investigating radiography to detect small voids inside the Nb EBW seam, where the target resolution is 0.1 mm. We are carrying out radiography tests with X-rays induced from an ultra short pulse intense laser. Recent progress will be presented.  
 
MOPB069 Study of HPR Created Oxide Layer at Nb Surfaces 336
 
  • P.V. Tyagi
    Sokendai, Ibaraki, Japan
  • H. Hayano, S. Kato, T. Saeki, M. Sawabe
    KEK, Ibaraki, Japan
 
  The performance of superconducting radio frequency (SRF) niobium (Nb) cavities strongly depends on final surface condition. Therefore the surface preparation of these SRF cavities often becomes critical. The preparation of surface includes two steps; surface chemistry (in order to get a smooth surface) and cleaning/rinsing (in order to remove contaminants left after the surface chemistry). As high pressure rinsing (HPR) with ultra pure water (UPW) is most commonly used surface cleaning method after the surface chemistry, it's very interesting to characterize the Nb surfaces after HPR. Results of our surface characterization done by XPS (x-ray photoelectron spectroscopy) with depth profiling show the presence of a thicker oxide surface characterization results show the presence of a thicker oxide layer at Nb surface as an outcome of HPR. In this article, we report the production of oxide layer (FWHM thickness) based on different conditions such as the pressures and doses.  
 
TH1A01 Results Achieved by the S1-Global Collaboration for ILC 748
 
  • H. Hayano, M. Akemoto, S. Fukuda, K. Hara, N. Higashi, E. Kako, H. Katagiri, Y. Kojima, Y. Kondo, T. Matsumoto, S. Michizono, T. Miura, H. Nakai, H. Nakajima, K. Nakanishi, S. Noguchi, N. Ohuchi, T. Saeki, T. Shidara, T. Shishido, T. Takenaka, A. Terashima, N. Toge, K. Tsuchiya, K. Watanabe, S. Yamaguchi, A. Yamamoto, Y. Yamamoto, K. Yokoya
    KEK, Ibaraki, Japan
  • C. Adolphsen, C.D. Nantista
    SLAC, Menlo Park, California, USA
  • T.T. Arkan, S. Barbanotti, M.A. Battistoni, H. Carter, M.S. Champion, A. Hocker, R.D. Kephart, J.S. Kerby, D.V. Mitchell, T.J. Peterson, Y.M. Pischalnikov, M.C. Ross, W. Schappert, B.E. Smith
    Fermilab, Batavia, USA
  • A. Bosotti, R. Paparella, P. Pierini
    INFN/LASA, Segrate (MI), Italy
  • K. Jensch, D. Kostin, L. Lilje, A. Matheisen, W.-D. Möller, P. Schilling, M. Schmökel, N.J. Walker, H. Weise
    DESY, Hamburg, Germany
  • C. Pagani
    Università degli Studi di Milano & INFN, Segrate, Italy
 
  The S1-Global collaboration (scope and plans presented at Linac10) ended successfully in 2011. In the S1-Global experiment several variants of ILC components (e.g. cavities, tuners, modules, couplers) proposed by all SCRF collaborators worldwide have been extensively tested and their performances compared, in order to build consensus for the technical choices towards the ILC TDR and to develop further the concept of plug-compatible components for ILC. The experiment has been carried at KEK with contribution of hardware and manpower from all collaborators.  
slides icon Slides TH1A01 [6.656 MB]