Keyword: superconducting-cavity
Paper Title Other Keywords Page
TUPOTK011 Commissioning of a New Magnetometric Mapping System for SRF Cavity Performance Tests cavity, SRF, niobium, ECR 1215
 
  • J.C. Wolff, J. Eschke, A. Gössel, D. Reschke, L. Steder, L. Trelle
    DESY, Hamburg, Germany
  • W. Hillert
    University of Hamburg, Institut für Experimentalphysik, Hamburg, Germany
 
  Funding: This work was supported by the Helmholtz Association within the topic Accelerator Research and Development (ARD) of the Matter and Technologies (MT) Program.
Magnetic flux trapped in the niobium bulk material of superconducting radio frequency (SRF) cavities degrades their quality factor and the accelerating gradient. The sensitivity for flux trapping is mainly determined by the treatment and the geometry of the cavity as well as the niobium grain size and orientation. To potentially improve the flux expulsion characteristics of SRF cavities and hence the efficiency of future accelerator facilities, further studies of the trapping behavior are essential. For this purpose a magnetometric mapping system to monitor the magnetic flux along the outer cavity surface of 1.3 GHz TESLA-Type single-cell SRF cavities has been developed and is currently in the commissioning phase at DESY. Contrary to similar approaches, this system digitizes the sensor signals already inside of the cryostat to extensively reduce the number of required cable feedthroughs. Furthermore, the signal-to-noise ratio (SNR) and consequently the measuring sensitivity can be enhanced by shorter analog signal lines, less thermal noise and the Mu-metal shielding of the cryostat. In this contribution test results gained by a prototype of the mapping system are presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOTK011  
About • Received ※ 10 June 2022 — Revised ※ 16 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 29 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOTK025 Design Study of the Third Harmonic Superconducting Cavity for a Bunch Lengthening cavity, status, vacuum, HOM 1258
 
  • J.Y. Yoon, E.-S. Kim
    KUS, Sejong, Republic of Korea
  • J.H. Han, H.S. Park
    Kiswire Advanced Technology Ltd., Daejeon, Republic of Korea
  • E. Kako
    KEK, Ibaraki, Japan
 
  The bunch lengthening by the 3rd harmonic cavity reduces the electron collisions in a bunch and increases the Touschek lifetime of a storage ring. We performed the multi-physics simulations including the electromagnetic, thermal, and mechanical analysis of the cavity. In the electromagnetic simulation, the geometry is optimized for the required performance of the cavity. The elliptical double-cell geometry is selected to increase the accelerating voltage and reduce the power losses of the cavity. Thermal/mechanical analyses were performed to check the deformation of the thermal and pressure contraction. The prototype cavity does not require the power coupler as it is a passive type. The conceptual design and copper prototype of the 3rd harmonic cavity will be described in this paper. Based on this design, the fabrication of Niobium cavity is in progress.
Superconducting RF, Cavity
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOTK025  
About • Received ※ 02 June 2022 — Revised ※ 13 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 09 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOTK054 Solid State Amplifiers for Beam Test System of PAPS at IHEP cavity, SRF, operation, status 1342
 
  • O. Xiao, Y.L. Chi, N. Gan, X.P. Li, Z.D. Zhang
    IHEP, People’s Republic of China
 
  Solid state amplifiers are being increasingly used as RF power sources in accelerators around the world. Two solid state amplifiers with different output power and frequen-cy have been applied in beam test system of PAPS at IHEP. A 10kW solid state amplifier operating at 1.3 GHz is used to feed a normal conducting buncher. A 650 MHz solid state amplifier with the output power of 150 kW is used to feed two 2-cell superconducting cavities. So far, the debugging and acceptance test of solid state amplifi-ers have been finished. During the beam test system commissioning and operation, all solid state amplifiers operate stably. In this paper, the specifications and high power test results of solid state amplifiers are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOTK054  
About • Received ※ 19 May 2022 — Revised ※ 10 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 06 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)