Author: Li, L.
Paper Title Page
TUPAB370 Development of Long Coil Dynamic Magnetic Field Measurement System for Dipole Magnets of HEPS Booster 2384
 
  • Y.Q. Liu, C.D. Deng, W. Kang, L. Li, S. Li, X. Wu, Y.W. Wu, J.X. Zhou
    IHEP, Beijing, People’s Republic of China
  • C.D. Deng, Y.W. Wu
    DNSC, Dongguan, People’s Republic of China
 
  A magnetic field measurement system for dipole magnets of High Energy Photon Source Booster is designed and developed. The system uses the long coil upflow method to measure the dynamic integral field of the magnet, and the long coil transverse-translation method to measure the integral field distribution error of the magnet. In this paper, the design and implementation of the magnetic measuring system are introduced in detail, and the magnetic field measurement results of the prototype magnet are shown. The measurement results show that the repeatability of the dynamic integral field measurement system is about 2 in 10,000, and the repeatability of the uniform distribution of the integral field is better than 1 in 10,000, which meets the test requirements of the discrete integral field of bulk magnets ±1 parts per thousand and the uniformity of the integral field ±5×10-4@6GeV and ±1×10-3 @0.5GeV.  
poster icon Poster TUPAB370 [1.475 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB370  
About • paper received ※ 16 May 2021       paper accepted ※ 16 June 2021       issue date ※ 17 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAB289 Design and Manufacture of Solenoid Center Deviation Measurement Device 4366
 
  • X. Wu, C.D. Deng, W. Kang, L. Li, S. Li, Y.Q. Liu, Y.W. Wu, J.X. Zhou
    IHEP, Beijing, People’s Republic of China
 
  The solenoids are widely used both in conventional magnets and superconducting magnets in particle accelerators. The longitudinal fields along the longitudinal direction of the solenoids are usually measured with the Hall probe measurement system. However, in some cases, the deviation between the magnetic center and mechanical center of the solenoid is another important parameter and has to be measured accurately. In this paper, a device is designed and developed to measure the center deviation of the solenoid, which can be both used in conventional magnets and superconducting magnets. After the device is finished, some tests are made in the solenoid to check whether the data is correct. For the numerical simulation and analysis of the magnetic field inside the solenoid, the TOSCA code was chosen right from start. The results of the analysis are compared to the result of the tests.  
poster icon Poster THPAB289 [1.001 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-THPAB289  
About • paper received ※ 14 May 2021       paper accepted ※ 27 July 2021       issue date ※ 22 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)