Author: Jadhav, P.S.
Paper Title Page
TUPAB404 Monte Carlo Studies for Shielding Design for High Energy Linac for Medical Isotope Generation 2469
 
  • N. Upadhyay, S. Chacko
    University of Mumbai, Mumbai, India
  • A.P. Deshpande, T.S. Dixit, P.S. Jadhav, R. Krishnan
    SAMEER, Mumbai, India
 
  The widely used radioactive tracer Technetium-99m (99mTc) is traditionally produced from Uranium via 235U (n, f) 99Mo reactions which depends heavily on nuclear reactors. Design studies for an alternative, cleaner approach for radioisotope generation using a high energy electron linac were initiated at SAMEER to generate 99Mo. The electron beam from a 30 MeV linac with an average current of 350 µA will be bombarded on a convertor target to produce X-rays which will be bombarded on enriched 100Mo target to produce 99Mo via (g, n) reaction. 99mTc will be eluted from 99Mo. The photons and neutrons produced in the process should be shielded appropriately to ensure radiation safety. This paper brings out the use of Monte Carlo techniques for photon and neutron shielding for our application. We used FLUKA to calculate the fluence, angular distribution and dose for photons and neutrons. Then, we introduced various layers of lead followed by HDPE, 5% borated HDPE and 40% boron rubber to ensure that the proposed shielding is sufficient to completely shield the photon as well as neutron radiation and hence is safe for operation.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB404  
About • paper received ※ 19 May 2021       paper accepted ※ 22 June 2021       issue date ※ 25 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB405 Design of High Energy Linac for Generation of Isotopes for Medical Applications 2472
 
  • A.P. Deshpande, S.R. Bhat, T.S. Dixit, P.S. Jadhav, A.S. Kottawar, R. Krishnan, M.S. Kumbhare, J. Mishra, C.S. Nainwad, S.R. Name, R. Sandeep Kumar, A. Shaikh, K.A. Thakur, M.M. Vidwans, A. Waingankar
    SAMEER, Mumbai, India
  • A.K. Mishra
    INMAS, New Delhi, India
  • N. Upadhyay
    University of Mumbai, Mumbai, India
 
  Funding: Ministry of Electronics and Information Technology (MeitY), Govt. of India.
After successful implementation of 6 and 15 MeV electron linear accelerator (linac) technology for Cancer Therapy in India, we initiated the development of high energy high current accelerator for the production of radioisotopes for diagnostic applications. The accelerator will be of 30 MeV energy with 350 µA average current provided by a gridded gun. The linac is a side coupled standing wave accelerator operating at 2998 MHz frequency operating at p/2 mode. The choice of p/2 operating mode is particularly suitable for this case where the repetition rate will be around 400 Hz. Klystron with 7 MW peak power and 36 kW average power will be used as the RF source. The modulator will be a solid-state modulator. The control system is FPGA based setup developed in-house at SAMEER. A retractable target with tungsten will be used as a converter to generate X-rays via bremsstrahlung. The x-rays will then interact with enriched 100Mo target to produce 99Mo via (g, n) reaction. Eluted 99mTc will be used for diagnostic applications. The paper lists the challenges and novel schemes developed at SAMEER to make a compact, rugged, and easy to use system keeping in mind local conditions.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB405  
About • paper received ※ 19 May 2021       paper accepted ※ 23 June 2021       issue date ※ 02 September 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)