MOPAB315 Beam Diagnostics for Commissioning and Operation of the FAIR Proton Linac 972
 
  • T. Sieber, P. Forck, S. Udrea
    GSI, Darmstadt, Germany
  • J. Herranz, A. Vizcaino-de-Julian
    Proactive Research and Development, Sabadell, Spain
 
  For the planned antiproton experiments at FAIR a dedicated proton injector Linac is currently under construction. It will be connected via the old UNILAC transfer beamline to SIS18 and has a length of ~30 m. The Linac will accelerate protons up to a final energy of 68 MeV, at a pulse length of 35 µs and a maximum repetition rate of 4 Hz. It will operate at 325 MHz and consists of a new so called "Ladder" RFQ type, followed by a chain of CH-cavities, partially coupled by rf-coupling cells. We have worked out a diagnostics system, which allows detailed measurement and study of all beam parameters during commissioning and later during regular operation. The diagnostics devices will - in a first step - be installed on a diagnostics testbench for stepwise commissioning. We present the concepts for Linac and testbench with some special emphasis on energy measurements with spectrometer and SEM Grid profile measurements.  
poster icon Poster MOPAB315 [3.149 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB315  
About • paper received ※ 14 May 2021       paper accepted ※ 24 June 2021       issue date ※ 30 August 2021  