Paper |
Title |
Page |
WEPAB347 |
Design, Construction and Testing of a Magnetic Probe for Fast Kicker Magnets |
3510 |
|
- N. Ayala, A. Ferrero Colomo, T. Kramer
CERN, Geneva 23, Switzerland
|
|
|
The CERN PS injection kicker has been modified in the framework of the LHC Injector Upgrade (LIU) project to allow injecting proton beams with an energy of 2 GeV. One of the most important items of the system parameter validation is the measurement and analysis of the magnetic field in the magnet aperture. To meet the required measurement precision without compromising the magnet vacuum performance, a dedicated magnetic probe has been designed, constructed and tested. The results are presented in this paper highlighting the mitigations of electrical, mechanical and vacuum complications. The paper concludes with an analysis of the probe performance during the first magnetic field measurements in the laboratory.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB347
|
|
About • |
paper received ※ 19 May 2021 paper accepted ※ 07 July 2021 issue date ※ 02 September 2021 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPAB354 |
Deployment and Commissioning of the CERN PS Injection Kicker System for Operation with 2 GeV Beams in Short Circuit Mode |
4489 |
|
- T. Kramer, N. Ayala, J.C.C.M. Borburgh, P.A.H. Burkel, E. Carlier, L. Ducimetière, L.M.C. Feliciano, A. Ferrero Colomo, M.A. Fraser, L.A. Govertsen, R. Noulibos, S. Pavis, L. Sermeus
CERN, Geneva, Switzerland
|
|
|
Within the framework of the LHC Injector Upgrade (LIU) project, the feasibility and design of an upgrade of the existing CERN PS proton injection kicker system have been outlined in previous publications already. This paper describes the adjustments of final design choices, testing, and deployment as well as the validation and commissioning of the new 2 GeV injection kicker system. The upgrade pays particular attention to the reduction of pulse reflections unavoidably induced by a magnet in short circuit mode configuration whilst keeping a fast 104 ns rise and fall time. An adapted thyratron triggering system to reduce jitter and enhance thyratron lifetime is outlined. Additionally, improvements to the magnet entry box and the elimination of SF6 gas in the magnet connection box and the associated pulse transmission lines are discussed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2021-THPAB354
|
|
About • |
paper received ※ 19 May 2021 paper accepted ※ 14 July 2021 issue date ※ 10 August 2021 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|