The Protection Instrument for Cryogenic Phase Separator Pressure Relief Valve of TPS Beamline |
1350 |
|
- C.C. Liang, C.Y. Chang, C.F. Chang, Y.H. Guo, M.H. Lee, C.Y.L. Liu, T.-C. Yu
NSRRC, Hsinchu, Taiwan
|
|
|
TPS (Taiwan Photon Source) beamlines have operated for three years after the successful commission in 2015. Recently, the electromagnetic activated pressure relief valve of cryogenic phase separator of beamline had malfunction due to the rust of its control circuits. After on site observation and temperature records, the water was found to be condensed around the outlet area due to fast temperature dropping near the valve as it was activated. Such situation would cause the rust of metal components due to humidity after a certain period of time. To avoid such event, fan is used to blow the condensed water and silicone heat belts are added to increase the local temperature with unique designed clamp for fixing the fan, sensors and safety circuit breaker. Via the temperature control system, the temperature monitoring, setting and the abnormal situation can be access on web page through Ethernet to make sure the proper operation of the protected devices. The instrument has been operated since Dec. 2018. After four months of operation, the moist situation has been improved and the relief valve is no longer frosted.
|
|