Paper |
Title |
Page |
WEPGW089 |
Calibration of the AWAKE Electron Spectrometer with Electrons Derived from a Partially Stripped Ion Beam |
2694 |
|
- D.A. Cooke, M. Cascella, J. Chappell, S. Jolly, F. Keeble, M. Wing
UCL, London, United Kingdom
- R. Alemany-Fernández, J. Bauche, I. Gorgisyan, E. Gschwendtner, V. Kain, M.W. Krasny, S. Mazzoni, A.V. Petrenko
CERN, Meyrin, Switzerland
- P. La Penna, M. Quattri
ESO, Garching bei Muenchen, Germany
|
|
|
The energy distribution of electrons accelerated in the wake of a self-modulated proton beam is measured using a magnetic spectrometer at AWAKE. The spectrometer was commissioned in 2017 and ran successfully throughout 2018. Imaging properties of the spectrometer system are studied via a combination of simulations and linear optics models and validated using mono-energetic electrons stripped from the partially stripped ion beam in the AWAKE beamline at CERN. These and other details of the calibration and performance will be presented.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW089
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPGW054 |
Generation and Delivery of an Ultraviolet Laser Beam for the RF-Photoinjector of the Awake Electron Beam |
3709 |
|
- V. Fedosseev, F. Batsch, C. Capelli, E. Chevallay, N. Chritin, S. Döbert, T. Feniet, F. Friebel, P. Gander, E. Granados, E. Gschwendtner, J. Hansen, C. Heßler, H. Panuganti, K.A. Szczurek
CERN, Meyrin, Switzerland
- M. Hüther, M. Martyanov, J.T. Moody, P. Muggli
MPI-P, München, Germany
|
|
|
In the AWAKE experiment, the electron beam is used to probe the proton-driven wakefield acceleration in a 10 m long rubidium vapor source. Electron bunches are produced using an RF-gun equipped with a Cs2Te photocathode illuminated by an ultraviolet (UV) laser pulse. To generate the UV laser beam a fraction of the infrared (IR) laser beam used for ionization of rubidium is extracted from the laser system, time-compressed to a picosecond scale and frequency tripled using nonlinear crystals. The transport line of the laser beam over the 20 m distance was built using rigid supports for mirrors and air-evacuated tube to prevent any possible beam pointing instabilities due to vibrations and air convection. Construction of the UV beam optical system enables appropriate beam shaping and control of its size and position on the cathode, as well as time delay with respect to the IR pulse, i.e. with respect to the plasma wakefield seeder. In this paper, we present the design of the UV beam line and results of its commissioning regarding IR/UV conversion, beam pointing stability, and means of beam control and monitoring.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPGW054
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 18 May 2019 issue date ※ 21 June 2019 |
|