Paper | Title | Page |
---|---|---|
WEPRB015 | Cleanroom Installations for SRF Cavities at the Helmholtz-Institut Mainz | 2830 |
|
||
At the Helmholtz-Institut Mainz (HIM) a cleanroom has been equipped with new tools and installations for the planned treatment of different superconducting RF-cavities. At first TESLA/XFEL type 9-cell cavities for the Mainz Energy-Recovering Superconducting Accelerator (MESA) project or 217 MHz multigap Crossbar H-mode cavities for the HElmholtz LInear ACcelerator (HELIAC) under development by HIM and GSI will be treated. The cleanroom installations, including the greyroom, cover an area of about 155 sqm. In its ISO-class 6 area a large ultrasonic and a conductance rinsing bath has been installed recently. A high pressure rinsing cabinet (HPR) has been implemented between the ISO-class 6 and 4 cleanroom. A RF-cavity can be loaded and unloaded from both sides. HPR treatments are possible for cavities of up to 1.4 m length and about 0.7 m diameter. For drying the ISO-class 4 clean room is equipped with a 160 C vacuum oven. New cleanroom lifters allow the handling of up to 200 kg heavy objects. A rail system in the cleanroom floor is installed to move out the entire cold string of the cleanroom after assembly and leak testing. First operational experiences with this facility will be presented. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPRB015 | |
About • | paper received ※ 29 April 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |