MOPMW019 Resonant Frequency Control with RCCS for the KOMAC Proton Linac 435
 
  • D.H. Seo, Y.-S. Cho, H.S. Kim, H.-J. Kwon, K.T. Seol, Y.G. Song
    Korea Atomic Energy Research Institute (KAERI), Gyeongbuk, Republic of Korea
 
  Funding: This work is supported by the Ministry of Science, ICT & Future Planning of the Korean Government.
The Resonance control cooling systems (RCCS) of 100 MeV proton linac at the Korea multi-purpose accelerator complex (KOMAC) have been operated for cooling the drift tubes (DT) and controlling the resonant frequency of the drift tube linac (DTL). The RCCS can maintain the cooling water temperature within ±0.1 °C by controlling 3-way valve opening. The RCCS has two types of control mode, the constant cooling water temperature control mode and the resonant frequency control mode. In the case of the resonant frequency control, the error frequency is measured in the low-level RF (LLRF) control system and the RCCS compensates the error frequency by controlling the cooling water temperature of DT with PID algorithm. In this paper, the operation results of the resonant frequency control with the RCCS as well as some modification of the LLRF system are presented.
 