Author: McCrady, R.C.
Paper Title Page
TUOAA01 Operation of LANSCE Linear Accelerator with Double Pulse Rate and Low Beam Losses 1004
 
  • Y.K. Batygin, J.S. Kolski, R.C. McCrady, L. Rybarcyk
    LANL, Los Alamos, New Mexico, USA
 
  Funding: Work supported by US DOE under contract DE-AC52-06NA25396
In 2014 LANSCE accelerator facility return to 120 Hz pulse rate operation after long period of operation at 60 Hz pulse rate. Increased capabilities require careful tuning of all components of linear accelerator. Transformation to double pulse rate resulted in re-evaluation of tuning procedures in order to meet new challenges in beam operation. The paper summarizes experimental activity on sustaining of high productivity of accelerator facility while keeping beam losses along accelerator at the low level.
 
slides icon Slides TUOAA01 [14.886 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUOAA01  