Author: Malyutin, D.
Paper Title Page
TUPOW003 High Average RF Power Tests With 2 RF Vacuum Windows at PITZ 1744
 
  • Y. Renier, G. Asova, M. A. Bakr, P. Boonpornprasert, J.D. Good, M. Groß, C. Hernandez-Garcia, H. Huck, I.I. Isaev, D.K. Kalantaryan, M. Krasilnikov, O. Lishilin, G. Loisch, D. Malyutin, D. Melkumyan, A. Oppelt, M. Otevřel, G. Pathak, T. Rublack, I.V. Rybakov, F. Stephan, G. Vashchenko, Q.T. Zhao
    DESY Zeuthen, Zeuthen, Germany
  • M. Bousonville, S. Choroba, S. Lederer
    DESY, Hamburg, Germany
 
  The Photo Injector Test facility at DESY, Zeuthen site (PITZ), was built with the aim to develop and characterize electron sources for future usage at FLASH and at the European XFEL. Recently, the main focus at PITZ has been the study of gun reliability and photoinjector performance at high average power. The goal is to get stable and reliable operation with 6.4 MW peak power in the gun at 650 us RF pulse length and 10 Hz repetition rate. To achieve this, a new RF feed system with two RF windows was installed at PITZ in 2014. During this test, the old gun 4.2 with a modified back-plane design for better cathode contact has been used. In this contribution the results of the RF conditioning of gun 4.2 with a detailed interlock analysis will be reported as well as results from recent electron beam characterization.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUPOW003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPMB009 Electron Beam Probe for the Bunch Length Measurements at BERLinPro 92
 
  • D. Malyutin, A.N. Matveenko
    HZB, Berlin, Germany
 
  For the successful operation of various accelerator facilities a detailed bunch characterization is required. A complete description can be achieved using various diagnostic systems installed along an accelerator beamline. Ideally the diagnostic should be able to measure parameters of a single bunch in a non-destructive manner. For bunch length measurements this results in a complicated task especially for bunch duration below 1 ps. One of the possible solutions is a diagnostic based on the interaction of a low energy electron beam with electro-magnetic fields of the relativistic bunch. The bunch length can be readily deduced from the resulting scatter. In this paper bunch length measurement technique based on a low energy electron beam is introduced. Results of numerical simulations of measurements are presented. A possible setup of such diagnostic system for BERLinPro facility is proposed.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB009  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOW034 Status Report of the Berlin Energy Recovery Linac Project BERLinPro 1827
 
  • M. Abo-Bakr, W. Anders, K.B. Bürkmann-Gehrlein, A.B. Büchel, P. Echevarria, A. Frahm, H.-W. Glock, F. Glöckner, F. Göbel, B.D.S. Hall, S. Heling, H.-G. Hoberg, A. Jankowiak, C. Kalus, T. Kamps, G. Klemz, J. Knobloch, J. Kolbe, G. Kourkafas, J. Kühn, B.C. Kuske, P. Kuske, J. Kuszynski, D. Malyutin, A.N. Matveenko, M. McAteer, A. Meseck, C.J. Metzger-Kraus, R. Müller, A. Neumann, N. Ohm, K. Ott, E. Panofski, F. Pflocksch, J. Rahn, J. Rudolph, M. Schmeißer, O. Schüler, M. Schuster, J. Ullrich, A. Ushakov, J. Völker
    HZB, Berlin, Germany
 
  Funding: Work supported by the German Bundesministerium für Bildung und Forschung, Land Berlin and grants of Helmholtz Association
The Helmholtz Zentrum Berlin is constructing the Energy Recovery Linac Prototype BERLinPro at the Berlin Adlershof site. The project is intended to expand the required accelerator physics and technology knowledge mandatory for the design, construction and operation of future synchrotron light sources. The project goal is the generation of a high current (100 mA), high brilliance (norm. emittance below 1 mm mrad) cw electron beam. We report on the project progress: since spring 2015 the building is under construction, ready for occupancy in January 2017. The planning phase for the first project stage is completed for the warm machine parts, the SRF gun and partly for the SRF booster. Most of the components have been ordered and are in fabrication with some already delivered. An update of the status of the various subprojects as well as a summary of future activities will be given. Project milestones and details of the timeline will be reviewed.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUPOW034  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOW007 Status and Prospects of the BESSY II Injector System 2826
 
  • T. Atkinson, W. Anders, P. Goslawski, A. Jankowiak, F. Kramer, P. Kuske, D. Malyutin, A.N. Matveenko, A. Neumann, M. Ries, M. Ruprecht, A. Schälicke, T. Schneegans, D. Schüler, P.I. Volz, G. Wüstefeld
    HZB, Berlin, Germany
  • H.G. Glass
    BESSY GmbH, Berlin, Germany
 
  The BESSY II injector system consists of a 50 MeV Linac, installed in preparation for TopUp operation, and a 10 Hz fast-ramping booster synchrotron. The system provides injection efficiencies into the BESSY II storage ring well above 90 % . This contribution reports on the present status, measurements of energy acceptance and other essential beam parameters as well as studies on coupled-bunch-by-bunch instability. Requirements for BESSY-VSR and possible upgrade scenarios are discussed.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOW007  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOW009 The Bessy Vsr Project for Short X-Ray Pulse Production 2833
 
  • A. Jankowiak, W. Anders, T. Atkinson, H. Ehmler, A. Föhlisch, P. Goslawski, K. Holldack, J. Knobloch, P. Kuske, D. Malyutin, A.N. Matveenko, R. Müller, A. Neumann, K. Ott, M. Ries, M. Ruprecht, A. Schälicke, A.V. Vélez, G. Wüstefeld
    HZB, Berlin, Germany
  • A. Burrill
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported by the German Bundesministerium für Bildung und Forschung, Land Berlin and grants of the Helmholtz Association
HZB has started the innovative project, BESSY VSR, to upgrade the 1.7 GeV synchrotron radiation source BESSY II. Its goal is to provide both 1.7 ps and 15 ps long, intense X-ray pulses simultaneously at all beam lines. These pulses are generated by enhanced longitudinal bunch focusing using superconducting 5-cell cavities operating at 1.5 GHz and 1.75 GHz. The resulting beating of the voltages creates alternating long and short buckets that can be custom filled. As a first major step, prototype superconducting cavities, initially only cooled to 4.4 K and thus operating at reduced voltage, will be installed into the BESSY II storage ring. Physical and technical aspects of this proposal where recently studied* and the results and project status are presented.
* A. Jankowiak, J. Knobloch for the BESSY VSR team, Technical Design Study BESSY VSR, doi:10.5442/R0001, Helmholtz-Zentrum Berlin (Germany), June 2015.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOW009  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)