Author: Delerue, N.
Paper Title Page
MOPMB002 First Measurements of Coherent Smith-Purcell Radiation in the SOLEIL Linac 69
 
  • N. Delerue, J. Barros, S. Jenzer, V. Khodnevych, M.S. Malovytsia
    LAL, Orsay, France
  • N. Hubert, M. Labat
    SOLEIL, Gif-sur-Yvette, France
  • V. Khodnevych
    National Taras Shevchenko University of Kyiv, The Faculty of Physics, Kyiv, Ukraine
  • M.S. Malovytsia
    KhNU, Kharkov, Ukraine
 
  Funding: The authors are grateful for the funding received from the French ANR (contract ANR-12-JS05-0003-01).
An experiment to measure the Coherent Smith-Purcell radiation has been installed in the SOLEIL Linac. Its aim is to produce a map of Smith-Purcell radiation emissions in several planes and compare it with theoretical predictions. Coherent Smith Purcell radiation is produced when a grating is brought close from a sufficiently short charged particles beam. The experiment consist of two detectors with 5 degrees of freedom. These two detectors can be moved around the emission point to measure the intensity of the radiation at different locations. Radiation maps are recorded parasitically by moving the detectors around during normal linac operations.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB002  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPMB003 Comparison of Coherent Smith-Purcell Radiation and Coherent Transition Radiation 72
 
  • V. Khodnevych, N. Delerue
    LAL, Orsay, France
  • O.A. Bezshyyko, V. Khodnevych
    National Taras Shevchenko University of Kyiv, The Faculty of Physics, Kyiv, Ukraine
 
  Funding: The authors are grateful for the funding received from the French ANR (contract ANR-12-JS05-0003-01) and the IDEATE International Associated Laboratory (LIA) between France and Ukraine.
Smith-Purcell radiation and Transition Radiation are two radiative phenomenon that occur in charged particles accelerators. For both the emission can be significantly enhanced with sufficiently short pulses and both can be used to measure the form factor of the pulse. We compare the yield of these phenomenon in different configurations and look at their application as bunch length monitors, including background filtering and rejection. We apply these calculations to the specific case of the CLIO Free Electron laser.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPMB004 Comparison of the Smith-purcell Radiation Yield for Different Models 75
 
  • M.S. Malovytsia, N. Delerue
    LAL, Orsay, France
  • M.S. Malovytsia
    KhNU, Kharkov, Ukraine
 
  Funding: The authors are grateful for the funding received from the French ANR (contract ANR-12-JS05-0003-01) and the IDEATE International Associated Laboratory (LIA) France-Ukraine.
Smith-Purcell radiation is used in several applications including the measurement of the longitudinal profile of electron bunches. A correct reconstruction of such profile requires a good understanding of the underlying model. We have compared the leading models of Smith-Purcell radiation and shown that they are in agreement within the experimental errors.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB004  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPMB005 Study of Short Bunches at the Free Electron Laser CLIO 78
 
  • V. Khodnevych, N. Delerue, S. Jenzer
    LAL, Orsay, France
  • J.P. Berthet, F. Glotin, J.-M. Ortega, R. Prazeres
    CLIO/ELISE/LCP, Orsay, France
  • V. Khodnevych
    National Taras Shevchenko University of Kyiv, The Faculty of Physics, Kyiv, Ukraine
 
  Funding: The authors are grateful for the funding received from the French ANR (contract ANR-12-JS05-0003-01).
CLIO is a Free Electron Laser based on a thermionic electron gun. In its normal operating mode it delivers electron 8 pulses but studies are ongoing to shorten the pulses to about 1 ps. We report on simulations showing how the pulse can be shortened and the expected signal yield from several bunch length diagnostics (Coherent Transition Radiation, Coherent Smith Purcell Radiation).
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB005  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPMR041 Experimental and Theoretical Studies of the Properties of Coherent Smith-Purcell Radiation 344
 
  • F. Bakkali Taheri, R. Bartolini, G. Doucas, I.V. Konoplev, A. Reichold
    JAI, Oxford, United Kingdom
  • J. Barros, N. Delerue
    LAL, Orsay, France
  • R. Bartolini
    DLS, Oxfordshire, United Kingdom
  • C.I. Clarke
    SLAC, Menlo Park, California, USA
 
  Funding: This work was supported (in parts) by the UK Science and Technology Facilities Council (STFC UK) through grant ST/M003590/1 and The Leverhulme Trust through the International Network Grant IN-2015-012
Previous studies have demonstrated that coherent Smith-Purcell radiation (cSPr) can be used for relativistic electron bunch time profile reconstruction at pico-second and femtosecond scales. The E203 experiments undertaken in May 2015 at FACET (SLAC) were dedicated to the study of some properties of cSPr, namely the azimuthal distribution and the polarization of the radiation. The experimental set up description which allowed such studies will be presented along with the results. To understand the experimental data both semi-analytical and numerical models were studied. The semi-analytical approach was based on the surface-current model, and the 3D particle-in-cell code VSim was used for numerical modeling. The experimental and theoretical studies are compared.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMR041  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPOW051 High Level Control Command for ThomX Transfer Line 830
 
  • C. Bruni, I. Chaikovska, S. Chancé, N. Delerue, A.R. Gamelin, H. Guler, H. Monard, C. Vallerand
    LAL, Orsay, France
  • A. Loulergue
    SOLEIL, Gif-sur-Yvette, France
 
  ThomX Compact X ray source is a 50 MeV storage ring, and a linear accelerator based on a photo-injector. As the electron beam in the ring will not be damped by synchrotron radiation, the transfer line should rely on a precise injection in the ring. In order to fulfill this requirement, especially in terms of optics function and orbit correction, different tools have been prepared and tested on the accelerator toolbox of Matlab Middle Layer. We will present the different tools and the underlying physics for the ThomX transfer line.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPOW051  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMY003 Simulations of the Acceleration of Externally Injected Electrons in a Plasma Excited in the Linear Regime 2542
 
  • N. Delerue, C. Bruni, S. Jenzer
    LAL, Orsay, France
  • S. Kazamias, B. Lucas, G. Maynard
    Laboratoire de Physique des Gaz et des Plasmas, Universite Paris-Sud, Orsay, France
  • M. Pittman
    CLUPS, Orsay, France
 
  We have investigated numerically the coupling between a 10 \si{MeV} electron bunch of high charge (§I{> 100}{pc}) with a laser generated accelerating plasma wave. Our results show that a high efficiency coupling can be achieved using a §I{50}{TW}, §I{100}{μ \meter} wide laser beam, yielding accelerating field above §I{1}{ GV/m}. We propose an experiment where these predictions could be tested.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPMY003  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMY004 Development of an Injector and a Magnetic Transfer Line in the Framework of Cilex 2545
 
  • A. Chancé
    CEA/DSM/IRFU, France
  • T. Audet, B. Cros, P. Lee, G. Maynard
    Laboratoire de Physique des Gaz et des Plasmas, Universite Paris-Sud, Orsay, France
  • M. Bougeard, S. Dobosz-Dufrénoy, A. Maitrallain
    CEA, Gif-sur-Yvette, France
  • N. Delerue
    LAL, Orsay, France
  • O. Delferrière, A. Mosnier, J. Schwindling
    CEA/IRFU, Gif-sur-Yvette, France
  • P. Monot
    CEA/DSM, Gif-sur-Yvette, France
  • A. Specka
    LLR, Palaiseau, France
 
  Funding: Investments for the Future program under reference ANR-10-EQPX-25, by the Triangle de la Physique under contract 2011-086TMULTIPLACCELE, 2012-032TELISA, and by the Labex PALM and P2IO.
Laser plasma accelerators (LPAs) have proven their capability to produce accelerating gradients three orders of magnitude higher than RF cavity-based accelerators. The present challenges of LPAs are to achieve the beam quality and stability required by users and to show the feasibility of plasma staging for high-energy applications. As one of the experiments planned at the PetaWatt laser APOLLON facility, currently under construction in France, aims at testing the two-stage scheme, a dedicated plasma injector which will be used as the first stage has been developed and tested at the UHI100 facility at CEA Saclay. The electron source, as well as the beam characterization line, will be presented and the first results will be discussed.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPMY004  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)