Author: Blomley, E.
Paper Title Page
MOPMB014 Simultaneous Detection of Longitudinal and Transverse Bunch Signals at ANKA 109
 
  • B. Kehrer, E. Blomley, M. Brosi, E. Bründermann, N. Hiller, A.-S. Müller, M.J. Nasse, M. Schedler, M. Schuh, P. Schönfeldt, P. Schütze, N.J. Smale, J.L. Steinmann
    KIT, Karlsruhe, Germany
 
  Funding: This work has been supported by the Initiative and Networking Fund of the Helmholtz Association under contract number VH-NG-320 and by the BMBF under contract number 05K13VKA.
The ANKA storage ring offers different operation modes including the short-bunch mode with bunch lengths tuned down to a few picoseconds. This can lead to the occurrence of micro-bunching instabilities coupled to the emission of coherent synchrotron radiation (CSR) in so-called 'bursts'. To study this CSR instability we use several turn-by-turn enabled detector systems to synchronously measure both the THz signal as well as bunch profiles. The different detectors are placed at different locations around the storage ring. Here we discuss the experimental setup and calibration of the various systems' synchronisation.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-MOPMB014  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOR006 Systematic Studies of Short Bunch-Length Bursting at ANKA 1662
 
  • M. Brosi, E. Blomley, E. Bründermann, N. Hiller, B. Kehrer, A.-S. Müller, M. Schedler, M. Schuh, P. Schönfeldt, J.L. Steinmann
    KIT, Karlsruhe, Germany
 
  Funding: Supported by the German Federal Ministry of Education and Research (05K13VKA), the Helmholtz Association (VH-NG-320) and by the Helmholtz International Research School for Teratronics (HIRST).
At ANKA, the Karlsruhe synchrotron radiation source, the so called short bunch-length operation mode allows the reduction of the bunch length down to a few picoseconds. The micro-bunching instability resulting from the high degree of longitudinal compression leads to fluctuations in the emitted intensity in the THz regime, referred to as bursting. For extremely compressed bunches at ANKA bursting also occurs, in a certain current range, below the main bursting threshold. This contribution shows measurements of this short bunch-length bursting and makes first comparisons with theory.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-TUPOR006  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOR001 Beam Studies with a New Longitudinal Feedback System at the ANKA Storage Ring 2658
 
  • E. Blomley, A.-S. Müller, M. Schedler
    KIT, Karlsruhe, Germany
 
  With the now fully commissioned longitudinal feedback system at the ANKA Storage Ring - in addition to the already operational transverse feedback system - the stability throughout the injection process was increased considerably. This opened up the possibility to investigate beam dynamics and limitations during injection more systematically. This paper presents the results of these studies, an overview of the limiting parameters and discusses possible approaches to increase the efficiency of the injection.  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOR001  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOW015 Influence of Filling Pattern Structure on Synchrotron Radiation Spectrum at ANKA 2855
SUPSS010   use link to see paper's listing under its alternate paper code  
 
  • J.L. Steinmann, E. Blomley, M. Brosi, E. Bründermann, C.M. Caselle, N. Hiller, B. Kehrer, A.-S. Müller, M. Schedler, M. Schuh, M. Schwarz, P. Schönfeldt, M. Siegel
    KIT, Karlsruhe, Germany
 
  Funding: This work is supported by the Helmholtz International School for Teratronics (HIRST)
We present the effects of the filling pattern structure in multi-bunch mode on the beam spectrum. This effects can be seen by all detectors whose resolution is better than the RF frequency, ranging from stripline and Schottky measurements to high resolution synchrotron radiation measurements. Our heterodyne measurements of the emitted coherent synchrotron radiation at 270 GHz reveal discrete frequency harmonics around the 100 000th revolution harmonic of ANKA, the synchrotron radiation facility in Karlsruhe, Germany. Significant effects of bunch spacing, gaps between bunch trains and variations in individual bunch currents on the emitted CSR spectrum are described by theory and supported by observations.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IPAC2016-WEPOW015  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)