Author: Oh, J.H.
Paper Title Page
MOPC036 Design of RF Cavity for Compact 9 MeV Cyclotron 151
 
  • H.S. Song, J.-S. Chai, H.W. Kim, B.N. Lee, J.H. Oh
    SKKU, Suwon, Republic of Korea
 
  The number of PET facility is rapidly increasing worldwide. To get PET image, circular accelerator such as cyclotron is needed. Compact 9 MeV H-cyclotron, which has a diameter of 1.25m is being designed at Sungkyunkwan University starting from July 2010 for getting F-18. It is expected to be constructed by next year. In this paper, RF system of 9 MeV cyclotron including design processes and detail analysis of result is reported. RF system mainly describes RF cavity design.  
 
WEPO011 Design study of Electromagnet for 13MeV PET Cyclotron 2415
 
  • B.N. Lee, J.-S. Chai, H.W. Kim, J.H. Oh, H.S. Song
    SKKU, Suwon, Republic of Korea
 
  Funding: National Research Foundation of Korea
Cyclotron electromagnet for RI production which is used for PET scanning has been designed. Designed pancake-shape electromagnet is an advanced type of KIRAMS-13's electromagnet which has the H-type electromagnet. The AVF structure with hill and valley was used for getting strong axial focusing and producing the energy of proton beam up to 13MeV with a thin stripper foil. To design and analyse the magnet, 3D CAD (CATIA V5)and TOSCA (OPERA-3D)were used, respectively. To reduce the calculation time, routine files were developed which can generate model, mesh and field map automatically in TOSCA modeller and post processor. The beam dynamics program OPTICY is used for calculation of the tunes.
KIRAMS-13* is the cyclotron had been manufactured by KIRAMS.
KIRAMS is short for Korea Institutes of Radiological and Medical Science.