Validation of a Micrometric Remotely Controlled Pre-alignment System for the CLIC Linear Collider using a Test Setup (Mock-up) with 5 Degrees of Freedom |
544 |
|
- H. Mainaud Durand, M. Anastasopoulos, J. Kemppinen, R. Leuxe, M. Sosin, S. griffet
CERN, Geneva, Switzerland
|
|
|
The CLIC main beam quadrupoles need to be pre-aligned within 17μm rms with respect to a straight reference line along a sliding window of 200 m. A re-adjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1 μm was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies.
|
|
|
MOPO030 |
Theoretical and Practical Feasibility Demonstration of a Micrometric Remotely Controlled Pre-alignment System for the CLIC Linear Collider |
547 |
|
- H. Mainaud Durand, M. Anastasopoulos, N.C. Chritin, J. Kemppinen, M. Sosin, S. griffet
CERN, Geneva, Switzerland
- T. Touzé
ENSTA, Brest, France
|
|
|
The active pre-alignment of the Compact Linear Collider (CLIC) is one of the key points of the project: the components must be pre-aligned w.r.t. to a straight line within a few microns over a sliding window of 200 m, along the two linacs of 20 km each. The proposed solution consists of stretched wires of more than 200 m, overlapping over half of their length, which will be the reference of alignment. Wire Positioning Sensors (WPS), coupled to the supports to be pre-aligned, will perform precise and accurate measurements within a few microns, w.r.t. these wires. A micrometric fiducialisation of the components and a micrometric alignment of the components on common supports will make the strategy of pre-alignment complete. In this paper, the global strategy of active pre-alignment is detailed and illustrated by the latest results demonstrating the feasibility of the proposed solution.
|
|
|