Author: Dorda, U.
Paper Title Page
THPS030 Layout and Optics of the MedAustron High Energy Beam Transfer Line 3484
 
  • U. Dorda, P.J. Bryant
    CERN, Geneva 23, Switzerland
  • M. Benedikt
    EBG MedAustron, Wr. Neustadt, Austria
 
  The MedAustron accelerator complex, which is currently in its final design stage at CERN, is based on the optical principles developed within the Proton Ion Medical Machine study (PIMMS) [bryantpimms]. This paper describes how these principles are practically applied in the layout and optics of the High Energy Beam Transfer line (HEBT) of the MedAustron accelerator facility. Special attention is directed to the optics of the gantry which is designed to fit into the PSI gantry-2 hardware layout, which is foreseen to be copied in collaboration with PSI.  
 
TUPC063 Energy Verification in Ion Beam Therapy 1141
 
  • F. Moser
    ATI, Wien, Austria
  • M. Benedikt, U. Dorda
    EBG MedAustron, Wr. Neustadt, Austria
 
  Funding: Austrian Federal Ministry for Science and Research, CERN Technology Doctoral Student Program
The adoption of synchrotrons for medical applications necessitates a comprehensive on-line verification of all beam parameters, autonomous of common beam monitors. In particular for energy verification, the required precision of down to 0.1 MeV, in absolute terms, poses a special challenge regarding the betatron-core driven 3rd order extraction mechanism which is intended to be used at MedAustron. Two different energy verification options have been studied and their limiting factors were investigated: 1) A time-of-flight measurement inside the synchrotron, limited by the orbit circumference information and measurement duration as well as extraction uncertainties. 2) A calorimeter-style system in the extraction line, limited by radiation hardness and statistical fluctuations. The paper discusses in detail the benefits and specific aspects of each method.
 
 
THPS029 Simulations of Various Driving Mechisms for the 3rd Order Resonant Extraction from the MedAustron Medical Synchrotron 3481
 
  • G. Feldbauer, M. Benedikt
    CERN, Geneva, Switzerland
  • U. Dorda
    EBG MedAustron, Wr. Neustadt, Austria
 
  The MedAustron medical synchrotron is based on the CERN-PIMMS design and its technical implementation by CNAO [1]. This document elaborates on studies performed on the baseline betatron-core driven extraction method and investigates the feasibility of alternative resonance driving mechanisms like RF-knockout, RF-noise and the lattice tune. Single particle tracking results are presented, explained and compared to analytical results.
[1] M. Pullia, ‘‘Status Report on the Centro Nazionale di Adroterapia Oncologica (CNAO)'', 11th EPAC'08, Genoa, Itlay, June 2008, p. 982