Paper |
Title |
Page |
S03SRD14 |
Control System for HIMAC Synchrotron |
156 |
|
- T. Kohno, K. Sato, E. Takada, K. Noda, A.I. Itano, M. Kanazawa, M. Sudou, K. Asami, R. Azumaishi, Y. Morii, N. Tsuzuki, H. Narusaka, Y. Hirao
NIRS, Chiba-shi, Japan
- K. Asami, R. Azumaishi
Hitachi, Ltd., Ibaraki-ken, Japan
- Y. Morii
TMEIC, Tokyo, Japan
- N. Tsuzuki
Toshiba Mitsubishi Electric Industrial Systems Corporation, Tokyo, Japan
- H. Narusaka
DEC-Japan, Tokyo, Japan
|
|
|
A control system for HIMAC synchrotron has been designed. The system consists of a main computer, console workstations, a few small computers and VME-computers connected via Ethernet. The small computers are dedicated to the control of an injection line, an extraction line and an RF system. Power supplies in main rings are controlled by the VME-computers through FDI/FDO, DI/DO modules. This paper describes an overview of the synchrotron control system.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-ICALEPCS1991-S03SRD14
|
|
About • |
Received ※ 11 November 1991 — Accepted ※ 20 November 1991 — Issued ※ 04 December 1992 |
|
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
S12FC07 |
RF Control System of the HIMAC Synchrotron |
434 |
|
- M. Kanazawa, Y. Hirao, A.I. Itano, K. Noda, K. Sato, M. Sudou, E. Takada
NIRS, Chiba-shi, Japan
- Y. Morii, M. Shigeta, E. Toyoda, N. Tsuzuki, T. Yagi, T. Yamagishi, C. Yamazaki
Toshiba Corporation, Tokyo, Japan
|
|
|
HIMAC is a heavy Ion accelerator facility dedicated to the medical use, especially for the clinical treatment of tumors. The ion species required for the clinical treatment range from 4He to 40Ar. An RF control system of the HIMAC synchrotron has been constructed. In this control system we have adopted a digital feed back system with a digital synthesizer (DS). Combining a high power system, performance of the control system have been tested in a factory (Toshiba) with a simulator circuit of the synchrotron oscillation. Following this test, we had beam acceleration test with this control system at TARN-II in INS (Institute for Nuclear Study, University of Tokyo). This paper describes the RF control system and its tested results.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-ICALEPCS1991-S12FC07
|
|
About • |
Received ※ 02 December 1991 — Accepted ※ 02 January 1992 — Issued ※ 04 December 1992 |
|