Author: Marcellini, F.
Paper Title Page
MO3C03 Development of the SLS 2.0 BPM System 15
 
  • B. Keil, R. Ditter, F. Marcellini, G.M. Marinkovic, J. Purtschert, M. Rizzi, M. Roggli, D. Stephan, X. Wang
    PSI, Villigen PSI, Switzerland
 
  After more than 20 years of operation, the storage ring of the Swiss Light Source (SLS) will be replaced. The new ring called SLS 2.0 will have 40 times higher brilliance than SLS, thanks to an innovative low-emittance magnet lattice and a beam pipe with smaller aperture. For SLS 2.0, the ageing SLS BPM electronics will be incrementally replaced for the whole accelerator, including linac, booster, transfer lines and storage ring. This contribution presents the development status and latest prototype test results of the SLS 2.0 BPM system, including BPM pickups, mechanics, and electronics.  
slides icon Slides MO3C03 [5.240 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-MO3C03  
About • Received ※ 09 September 2023 — Revised ※ 10 September 2023 — Accepted ※ 14 September 2023 — Issue date ※ 21 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOP010 Diagnostics for a High Emittance and High Energy Spread Positron Source 54
 
  • N. Vallis, P. Craievich, R.F. Fortunati, R. Ischebeck, E. Ismaili, P.N. Juranič, F. Marcellini, G.L. Orlandi, M. Schaer, R. Zennaro, M. Zykova
    PSI, Villigen PSI, Switzerland
 
  Funding: This work was done under the auspices of CHART (chart.ch)
This paper is an overview of a diagnostics setup for highly spread e⁺e⁻ beams, to be installed at the PSI Positron Production (P3 or P-cubed) experiment. To be hosted at the SwissFEL facility (PSI, Switzerland) in 2026, P3 is e+ source demonstrator designed to generate, capture, separate and detect nano-Coulombs of secondary e+ and e- bunches, in spite of their extreme tranverse emittance and energy spread. The experiment will employ an arrangement of broadband pick-ups (BBPs) to detect simultaneously the time structure of secondary e⁺e⁻ bunches. A spectrometer will follow the BBPs and deflect the e+ and e- onto two unconventional faraday cups that will measure their charge. In addition, the energy spectrum of e+ and e- distribution will be reconstructed through scintillating fibers.
 
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-MOP010  
About • Received ※ 05 September 2023 — Revised ※ 07 September 2023 — Accepted ※ 13 September 2023 — Issue date ※ 25 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)