MOPP04 Conceptual Design Overview of the Electron Ion Collider Instrumentation 30
 
  • D.M. Gassner, M. Blaskiewicz, K.A. Drees, T. Hayes, C. Hetzel, D. Holmes, R.L. Hulsart, P. Inacker, C. Liu, R.J. Michnoff, M.G. Minty, C. Montag, D. Padrazo Jr, M.C. Paniccia, V. Ptitsyn, V.H. Ranjbar, M.P. Sangroula, T.V. Shaftan, P. Thieberger, E. Wang, F.J. Willeke
    BNL, Upton, New York, USA
  • J.R. Bellon, A. Blednykh
    Brookhaven National Laboratory (BNL), Electron-Ion Collider, Upton, New York, USA
  • L.R. Dalesio
    Osprey DCS LLC, Ocean City, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Con-tract No. DE-SC0012704 with the U.S. Department of Energy.
A new high-luminosity Electron Ion Collider (EIC) is being developed at Brookhaven National Laboratory (BNL). The conceptual design [1] has recently been completed. The EIC will be realized in the existing RHIC facility. In addition to improving the existing hadron storage ring instrumentation, new electron accelerators that include a 350 keV gun, 400 MeV Linac, a rapid-cycling synchrotron, an electron storage ring, and a strong hadron cooling facility will all have new instrumentation systems. An overview of the conceptual design of the beam instrumentation will be presented.
 
poster icon Poster MOPP04 [4.645 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2021-MOPP04  
About • paper received ※ 08 September 2021       paper accepted ※ 17 September 2021       issue date ※ 15 October 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPP20 Beam Position Monitor Calibration by Rapid Channel Switching 84
 
  • R.L. Hulsart, R.J. Michnoff, S. Seletskiy, P. Thieberger
    BNL, Upton, New York, USA
 
  One of the requirements for low-energy RHIC electron cooling (LEReC) is a small relative angle between the ion and electron beams as they co-propagate. In order to minimize relative electron-ion trajectories angle, BPM measurements of both beams must be very accurate. Achieving this requires good electronic calibration of the associated cables and RF components, due to their inherent imperfections. Unfortunately, these are typically frequency dependent, especially in the RF filter and amplifier stages. The spectral content of the ion vs. electron bunch signals varies significantly, presenting a calibration challenge, even when using the same sampling channels and electronics to measure both beams. A scheme of rapidly swapping the BPM signals from the pickup electrodes between the two signal cables (and sampling channels), using switches installed near the BPM was implemented to combat these calibration is-sues. Bias in each signal path appears as an offset which has an equal and opposite component when the cables are reversed. Taking the average of the two measurements with the channels in normal and reverse positions reduces this offset error. Successful transverse cooling of the RHIC ion beam has been verified after using this switching technique to provide continuous calibration of the BPM electronics [1]. Details of the processing hard-ware and switch control methodology to achieve this result will be discussed.  
poster icon Poster MOPP20 [0.491 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2021-MOPP20  