Paper | Title | Other Keywords | Page |
---|---|---|---|
MOPG32 | Beam Diagnostics for the Multi-MW Hadron Linac IFMIF/DONES | diagnostics, target, beam-diagnostic, linac | 111 |
|
|||
Funding: This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014-2018 under grant agreement No 633053 In the frame of the material research for future fusion reactors, the construction of a simplified facility of IFMIF*, the so-called IFMIF/DONES** (Demo-Oriented Neutron Early Source), to generate sufficient material damage for the new design of DEMO . DONES will be a 40 MeV, 125 mA deuteron accelerator. The 5 MW beam will impact in a lithium flow target to yield a neutron source The detailed design of the DONES accelerator is being designed within EUROFUSION-WPENS project. One of the most critical tasks of the accelerator will be to identify the layout of beam diagnostics along the accelerator. This instrumentation must guarantee the high availability of the whole accelerator system and the beam characteristics and machine protection. This contribution will describe the beam diagnostics selected along the accelerator, focusing in the High Energy Beam Transport line, in charge of shaping the beam down to the high power target. The main open questions will be analyzed and the path to obtain the detailed design by the end of the project detailed. *, IFMIF Intermediate Engineering Design Report **, DONES Conceptual Design Report, April 2014 |
|||
DOI • | reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG32 | ||
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||