Keyword: site
Paper Title Other Keywords Page
WEPG39 Measurement Uncertainty Assessments of the SPIRAL2 ACCT/DCCT controls, linac, electronics, rfq 712
 
  • S.L. Leloir, T.A. Andre, C. Jamet, G. Ledu, S. Loret, C. Potier de courcy
    GANIL, Caen, France
 
  Four instrumentation chains with AC and DC Current Transformers (ACCT-DCCT) will equip the lines of SPIRAL2 facility to measure the beam intensity and line transmissions. These measures are essential to tune and supervise the beam, to assure the thermal protection of the accelerator and to control that the intensities and transmissions are below the authorized limits. As such, the uncertainties of measurement chains must be taken into account in the threshold values. The electronic has been designed with high requirements of quality and dependability by following different steps; from prototyping, the qualification through an Analysis of Failure Modes and Effects Analysis (FMEA) until final fabrication. This paper presents the measurement uncertainty assessments of the ACCT/DCCT chains.  
poster icon Poster WEPG39 [0.551 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-WEPG39  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)