Author: Czuba, K.
Paper Title Page
THP2WB03 Influence of the Cavity Field Flatness and Effect of the Phase Reference Line Errors on the Beam Dynamics of the ESS Linac 377
 
  • R. De Prisco, R. Zeng
    ESS, Lund, Sweden
  • K. Czuba, T.P. Leśniak, R. Papis, D. Sikora, M. Żukociński
    Warsaw University of Technology, Institute of Electronic Systems, Warsaw, Poland
 
  The particle longitudinal dynamics is affected by errors on the phase and amplitude of the electro-magnetic field in each cavity that cause emittance growth, beam degradation and losses. One of the causes of the phase error is the change of the ambient temperature in the LINAC tunnel, in the stub and in the klystron gallery that induces a phase drift of the signal travelling through the cables and radio frequency components. The field flatness error of each multiple cell cavity is caused by volume perturbation, cell to cell coupling, tuner penetration, etc.. In this paper it is studied the influences of these two types of errors on the beam dynamics and it is determined their tolerances such that the beam quality is kept within acceptable limits.  
slides icon Slides THP2WB03 [1.556 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-HB2018-THP2WB03  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)