Author: Qian, H.J.
Paper Title Page
WEP005 Coaxial Coupler RF Kick in the PITZ RF Gun 422
 
  • Y. Chen, P. Boonpornprasert, J.D. Good, H. Huck, I.I. Isaev, M. Krasilnikov, A. Oppelt, H.J. Qian, Y. Renier, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
  • W. Ackermann, H. De Gersem
    TEMF, TU Darmstadt, Darmstadt, Germany
  • M. Dohlus
    DESY, Hamburg, Germany
  • Q.T. Zhao
    IMP/CAS, Lanzhou, People's Republic of China
 
  We investigate a transverse RF kick induced by the transition between rectangular waveguide and coaxial line of the RF coupler in the 1.6-cell L-band normal conducting (NC) RF gun at the Photo Injector Test Facility at DESY, Zeuthen site (PITZ). A three-dimensional electromagnetic simulation shows the disturbed RF field distributions in the fundamental accelerating mode. Based on the 3D RF field map, an electron beam based characterization and quantification of the coaxial coupler RF kick in the PITZ gun is simulated. Preliminary results of the investigations are presented.  
poster icon Poster WEP005 [1.345 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2017-WEP005  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP006 Preliminary On-Table and Photoelectron Results from the PITZ Quasi-Ellipsoidal Photocathode Laser System 426
 
  • J.D. Good, G. Asova, P. Boonpornprasert, Y. Chen, M. Groß, H. Huck, I.I. Isaev, D.K. Kalantaryan, M. Krasilnikov, X. Li, O. Lishilin, G. Loisch, D.M. Melkumyan, A. Oppelt, H.J. Qian, Y. Renier, T. Rublack, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
  • A.V. Andrianov, E. Gacheva, E. Khazanov, S. Mironov, A. Poteomkin, V. Zelenogorsky
    IAP/RAS, Nizhny Novgorod, Russia
  • I. Hartl, S. Schreiber
    DESY, Hamburg, Germany
  • E. Syresin
    JINR, Dubna, Moscow Region, Russia
 
  The optimization of photoinjectors is crucial for the successful operation of linac-based free electron lasers, and beam dynamics simulations have shown that ellipsoidal photocathode laser pulses result in significantly lower electron beam emittance than that of conventional cylindrical pulses. Therefore, in collaboration with the Institute of Applied Physics (Nizhny Novgorod, Russia) and the Joint Institute of Nuclear Research (Dubna, Russia), a laser system capable of generating quasi-ellipsoidal laser pulses has been developed and installed at the Photo Injector Test facility at DESY, Zeuthen site (PITZ). The pulse shaping has been realized using the spatial light modulator technique, characterized by cross-correlation and spectrographic measurements, and is demonstrated with electron beam measurements. In this contribution the overall setup, operating principles, and results of first regular electron beam measurements will be presented together with corresponding beam dynamics simulations. Furthermore, the numerous improvements of the simplified re-design currently under construction shall be detailed.  
poster icon Poster WEP006 [1.766 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2017-WEP006  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP007 Electron Beam Asymmetry Compensation with Gun Quadrupoles at PITZ 429
 
  • M. Krasilnikov, P. Boonpornprasert, Y. Chen, J.D. Good, M. Groß, H. Huck, I.I. Isaev, D.K. Kalantaryan, X. Li, O. Lishilin, G. Loisch, D.M. Melkumyan, A. Oppelt, H.J. Qian, Y. Renier, F. Stephan, Q.T. Zhao
    DESY Zeuthen, Zeuthen, Germany
  • G.A. Amatuni, B. Grigoryan
    CANDLE SRI, Yerevan, Armenia
  • G. Asova
    INRNE, Sofia, Bulgaria
  • Q.T. Zhao
    IMP/CAS, Lanzhou, People's Republic of China
 
  The electron beam asymmetry observed at the Photo Injector Test Facility at DESY in Zeuthen (PITZ) was traced back to multipole kicks in the gun section, namely around the location of the coaxial power coupler and the main solenoid. Several dedicated studies have been performed to quantify the kick location and strength. Based on these studies, two designs of correction quadrupole coils were proposed. The coils were fabricated and tested with an electron beam. The second updated design implies a two quadrupole setup on a frame installed around the gun coaxial coupler close to the main solenoid centre location. Skew and normal quadrupole magnets are powered independently, enabling flexibility in electron beam manipulations. By means of this setup, a more symmetric beam was obtained at several screens. This led also to more equal measured horizontal and vertical phase spaces and to even smaller overall emittance values. Some details of the gun quadrupole designs, magnetic measurements, and results of electron beam measurements including emittance optimization will be reported.  
poster icon Poster WEP007 [1.997 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2017-WEP007  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP008 Beam Brightness Improvement by Ellipsoidal Laser Shaping for CW Photoinjectors 432
 
  • H.J. Qian, M. Krasilnikov, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
 
  High-brightness photoinjectors operating in a continuous wave (CW) mode are required for many advanced applications, such as CW X-ray FEL, ERL light source, electron coolers for hadron beams and electron-ion colliders and so on. Now, three types of CW electron guns are available: DC gun, SRF gun and normal conducting RF gun, which are under intense development in different institutes based on local expertise and application demands. Compared to pulsed guns, both beam energy and brightness from CW guns are compromised due to a lower acceleration gradient. Flattop laser shaping has been applied in both pulsed and CW guns to improve beam emittance. In this paper, ellipsoidal laser shaping is applied in CW photoinjectors to improve beam brightness, and preliminary ASTRA simulations are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2017-WEP008  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP009 A Cryocooled Normal-Conducting and Superconducting Hybrid CW Photoinjector 436
 
  • H.J. Qian, M. Krasilnikov, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
 
  Continuous wave (CW) photoinjectors have seen great progress in the last decades, such as DC gun, SRF gun and normal conducting VHF-band RF gun. New developments of CW guns are aiming higher acceleration gradient and beam energy for higher-beam brightness. One of the technical challenges for CW SRF guns is the compatibility of normal-conducting high QE cathodes and superconducting cavity. In this paper, a high gradient cryocooled CW normal-conducting gun is proposed to house the high QE cathode, and a SRF cavity nearby gives further energy acceleration. Preliminary ASTRA simulations of such a hybrid photoinjector are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2017-WEP009  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP010 Beam Asymmetry Studies with Quadrupole Field Errors in the PITZ Gun Section 440
 
  • Q.T. Zhao, G. Asova, P. Boonpornprasert, Y. Chen, J.D. Good, M. Groß, H. Huck, I.I. Isaev, D.K. Kalantaryan, M. Krasilnikov, X. Li, O. Lishilin, G. Loisch, D.M. Melkumyan, A. Oppelt, H.J. Qian, Y. Renier, T. Rublack, C. Saisa-ard, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
  • G. Asova
    INRNE, Sofia, Bulgaria
  • C. Saisa-ard
    Chiang Mai University, Chiang Mai, Thailand
  • Q.T. Zhao
    IMP/CAS, Lanzhou, People's Republic of China
 
  The Photo Injector Test Facility at DESY in Zeuthen (PITZ) was built to test and optimize high-brightness electron sources for free electron lasers (FELs) like FLASH and European XFEL. Although the beam emittance has been optimized and experimentally demonstrated to meet the requirements of FLASH and XFEL, transverse beam asymmetries, such as wing structures and beam tilts, were observed during many years of operation with different generations of guns. These cannot be explained by simulations with the rotationally symmetric gun cavities and symmetric solenoid fields. Based on previous RF coupler kick, solenoid field imperfection studies and coupling beam dynamics, the beam asymmetries most probably stem from rotated quadrupole field error in the gun section. A thin-lens static quadrupole model is applied in the RF gun section simulations to fit the position and intensity of quadrupole field errors by comparing the beam asymmetry directions in experiments and ASTRA simulations. Furthermore, by measuring the laser position movement at the photo cathode and the corresponding beam movement at downstream screens, the integrated quadrupole field strength can also be extracted.  
poster icon Poster WEP010 [1.856 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2017-WEP010  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)