A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Kasemir, K.-U.

Paper Title Page
TUPC140 The Spallation Neutron Source Cryomodule Test Stand RF System 1395
 
  • M. T. Crofford, T. W. Hardek, D. Heidenreich, Y. W. Kang, K.-U. Kasemir, S.-H. Kim
    ORNL, Oak Ridge, Tennessee
  • J. A. Ball, T. L. Davidson
    ORNL RAD, Oak Ridge
 
  The Spallation Neutron Source (SNS) has recently commissioned a cryomodule test facility for the repair and testing of the super-conducting cryogenic cavities. This facility utilizes the original 402.5/805 MHz Radio Frequency (RF) Klystron Test Stand as its power source along with dual Low Level RF (LLRF) control systems. One control system is based on the standard SNS Linac LLRF controls with a second system for open-loop only control. The system is designed to allow simultaneous testing of devices in the test cave and other devices which can be tested outside of the enclosure. Initial tests have shown good results; some improvements are yet to be implemented. This paper will provide an overview of the RF systems, safety systems, and interlocks.