A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Kim, J.H.

Paper Title Page
TUPCH137 Design of the RF System for 30 MeV Cyclotron 1340
 
  • I.S. Jung, D.H. An, J.-S. Chai, H.B. Hong, S.S. Hong, M.G. Hur, H.S. Jang, J. Kang, J.H. Kim, Y.-S. Kim, M.Y. Lee, T.K. Yang
    KIRAMS, Seoul
  • K.H. Kwon
    SKKU, Seoul
 
  LAD (Lab. of Accelerator Development) in KIRAMS (Korea Institute of Radiological & Medical Sciences) developed 13MeV medical cyclotron, named by KIRAMS-13, for PET (Positron Emission Tomography) in 2001. Now, KIRAMS-13 is widespread in Korea through the national project, "Development of Cyclotron and FDG Synthesis module." But, there is just one cyclotron for SPECT(Single Photon Emission Computed Tomography) in Korea, which is made by IBA, Belgium. If some problems are happened, we should shut off the cyclotron until IBA engineer fixes them. So, we decide to develop a 30MeV cyclotron, named KIRAMS-30, which has high-performance compared with existing commercial cyclotrons and will install this machine to radioactive isotopes production and researches in Advanced Radiation Technology Institute. In this paper, we design RF system, such as cavity, power coupler, and so on. At design of RF components, we consider mechanical stability, RF heating and cooling, arcing and multipacting, low maintenance. We simulate KIRAMS-30 with MWS (MicroWave Studio) and present simulation results.  
WEPCH080 Beam Simulation of SQQ Injection System in KIRAMS-30 Cyclotron 2107
 
  • D.H. An, J.-S. Chai, H.B. Hong, S.S. Hong, M.G. Hur, W.T. Hwang, H.S. Jang, I.S. Jung, J. Kang, J.H. Kim, Y.S. Kim, M.Y. Lee, T.K. Yang
    KIRAMS, Seoul
 
  The injection system of KIRAMS-30 cyclotron consists of a double gap buncher, an SQQ, and a spiral inflector. Initial beam with 100 mmmrad has been generated by random Gaussian function in the transverse plane and random uniform function in the longitudinal direction. Using the 3D electric and magnetic fields of a buncher, SQQ, inflector, and return-yoke bore, the characteristics of the beam injected into the KIRAMS-30 cyclotron's central region has been obtained. This paper presents the results of its beam characteristics and parameters of each beam element.  
WEPLS132 New Magnet Power Supply for PAL Linac 2685
 
  • S.-C. Kim, J. Choi, K.M. Ha, J.Y. Huang, J.H. Kim, S.H. Kim, I.S. Ko, S.S. Park
    PAL, Pohang, Kyungbuk
 
  Since the completion of PLS in 1994, PLS Linac magnet power supply(MPS) has been operated for 12 years with 12-bit resolution and 0.1% stability. Improvement in the resolution and the reliability of the Linac MPS is highly required now for the stable beam injection and 4th generation light source research. To improve MPS, we developed new compact MPS of 16-bit resolution and 20ppm stability using four-quadrant switching scheme with 50kHz MOSFET switching device. Bipolar MPS for corrector magnet consists of main power board, control power board, regulator board and CPU board. Size of each board is only 100mm width and 240mm depth. Unipolar MPS for quadrupoles and solenoid magnets is composed by parallel-operation of two main power boards, doubling the current output. Output of MPS is 10V, ±10A for the bipolar and 50V, 50A for the unipolar magnet. In this paper, we report on the development and characteristics of the new MPS for PAL linac.  
THPCH177 Design and Construction of the PEFP Timing System for a 20 MeV Proton Beam 3212
 
  • Y.-G. Song, Y.-S. Cho, H.M. Choi, I.-S. Hong
    KAERI, Daejon
  • K.M. Ha, J.H. Kim
    PAL, Pohang, Kyungbuk
 
  The timing system of the PEFP requires synchronization for the accelerator and for the multipurpose beam line. The system is based on an event distribution system that broadcasts the timing information globally to all the equipment. Fast I/O hardware of the timing system is to distribute appropriate timing signals to accelerator systems, including the Injector, RFQ, DTL, and user's facilities. Signals to be distributed include the synchronized pulse triggers and event information of RF system and switching magnet power supplies for the 20MeV proton beam extraction.