A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Junquera, T.

Paper Title Page
MOPCH145 Tests Results of the Beta 0.07 and Beta 0.12 Quarter Wave Resonators for the SPIRAL2 Superconducting Linac 393
 
  • G. Olry, J.-L. Biarrotte, S. Bousson, C. Joly, T. Junquera, J. Lesrel, G. Martinet, D. Moura, H. Saugnac, P. Szott
    IPN, Orsay
  • P.-E. Bernaudin, P. Bosland, G. Devanz
    CEA, Gif-sur-Yvette
 
  New developments and tests have been carried out on low beta (0.07) and high beta (0.12) 88 MHz superconducting Quarter Wave Resonators. These resonators will be installed in the LINAC driver, respectively in the low beta section, composed of cryomodules A (developed at CEA-Saclay) and the high beta section composed of cryomodules B (developed at IPN-Orsay). Both resonators' types will be equipped with the same power coupler (developed at LPSC-Grenoble) and designed for a maximum power of 20 kW. RF tests results of the prototype cavities and power couplers are reported. The fabrication of the two cryomodules prototypes, fully equipped, is in progress in order to be ready for high power RF tests at 4.2 K at the beginning of 2007.  
MOPCH146 Status of the Beta 0.12 Superconducting Cryomodule Development for the Spiral2 Project 396
 
  • H. Saugnac, J.-L. Biarrotte, S. Blivet, S. Bousson, C. Commeaux, C. Joly, T. Junquera, J. Lesrel, fl. Lutton, G. Martinet, G. Olry, P. Szott
    IPN, Orsay
 
  SPIRAL2 is a radioactive beams facility, composed of a superconducting linac driver, delivering deuterons with an energy up to 40 MeV (5 mA) and heavy ions with an energy of 14.5 MeV/u (1 mA). This facility is now fully approved by the French government. IPN Orsay is in charge of the study and manufacture of the beta 0.12 cryomodule of the superconducting LINAC. These cryomodule, designed for an overall cryogenic power of 30 W at 4.2 K, is composed of two quarter wave type 88 MHz rf resonator providing a minimum of 6.5 MV/m with a quality factor of 1 10 9, two tuning mechanisms controlling the resonator frequency and an alignment system allowing to adjust the cavity position with a ± 1 mm accuracy. Several tests performed on a first resonator prototype fabricated by the "Ettore Zanon SpA" Company, have validated the cavity and its auxiliary components design. A first cryomodule fully equipped (cavities, cryostat, tuning and alignment systems), planned to be tested at the beginning of 2007, is under manufacturing. The details of the cryomodule design and the resonator tests results are discussed in the paper.  
TUPLS032 Superconducting Driver Linac for the New Spiral 2 Radioactive Ion Beam Facility GANIL 1559
 
  • T. Junquera
    IPN, Orsay
 
  The new Spiral 2 facility will deliver high intensity rare isotope beams for fundamental research in nuclear physics, and high neutron flux for multidisciplinary applications. Based into the ISOL and in-flight isotope production methods this facility will cover broad areas of the nuclide chart. The driver accelerator must deliver CW beams of deuterons (40 MeV, 5 mA) and heavy ions (q/A=1/3, 15 MeV/A, 1 mA). The injector is composed of two ion sources (deuterons and heavy ions) and a common RFQ cavity (88 MHz). The Superconducting Linac is composed of two sections of Quarter Wave Resonators (beta 0.07 and 0.12, frequency 88 MHz) with room temperature focusing devices. After two years of preliminary study, and following the recent decision to launch the construction phase, a complete design of the Driver Accelerator is presently completed. Important results have been obtained during the initial R&D phase, in particular on ion sources, RFQ and superconducting resonators prototypes. Status report on both the design and the prototype performances will be given in this contribution.