A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Jankowiak, A.

Paper Title Page
MOPLS116 Status Report on the Harmonic Double-sided Microtron of MAMI C 834
 
  • A. Jankowiak, K. Aulenbacher, O. Chubarov, M. Dehn, H. Euteneuer, F.F. Fichtner, F. Hagenbuck, R.H. Herr, P. Jennewein, K.-H. Kaiser, W.K. Klag, H.J. Kreidel, U.L. Ludwig-Mertin, J.R. Röthgen, S.S. Schumann, G.S. Stephan, V. Tioukine
    IKP, Mainz
 
  The Mainz Mikrotron MAMI is a cascade of three racetrack microtrons, delivering since 1991 a high quality 855MeV, 100muA cw electron beam for nuclear and radiation physics experiments. An energy upgrade of this machine to 1.5GeV by adding a Harmonic Double-Sided Microtron (HDSM)* as a fourth stage is well under way. Here we give a review of the experiences gained during fabrication and testing of the main components of the HDSM and report the status of its construction. Initial operation of the machine is expected for the first half of 2006. After a period of commissioning in diagnostic pulse mode with low beam power (10ns, high intensity bunch trains with a repetition rate of max. 10kHz), soon the first nuclear physics experiments will be started.

*A. Jankowiak et al. "Design and Status of the 1.5 GeV-Harmonic Double Sided Microtron for MAMI", Proceedings EPAC2002, Paris, p. 1085.

 
TUPCH033 Automated Beam Optimisation and Diagnostics at MAMI 1076
 
  • M. Dehn, H. Euteneuer, F.F. Fichtner, A. Jankowiak, K.-H. Kaiser, W.K. Klag, H.J. Kreidel, S.S. Schumann, G.S. Stephan
    IKP, Mainz
 
  At the Institut fur Kernphysik (IKPH) of Mainz University the fourth stage of the Mainz Microtron (MAMI), a 855MeV to 1500MeV Harmonic Double Sided Microtron (HDSM), is now on the verge of first operation*. To provide an automated beam optimisation, low-Q-TM010 and TM110 resonators at each linac of the three cascaded RTMs and the two linacs of the new HDSM are used. These monitors deliver position, phase and intensity signals of each recirculation turn when modulating the beam intensity with 12ns-pulses (diagnostic pulses, max. rep. rate 10kHz). For operating the HDSM an extended system for displaying and digitising these signals was developed. High-bandwidth ADCs allow very comfortable to analyse, calibrate and automatically optimise the beam positions and phases during operation. The system is also used to adjust the transversal and longitudinal focussing according to the design parameters. Synchrotron radiation monitors, providing beam sizes and positions out of the bending magnets for each turn and on the entrance and exit of the linac axis, were a very helpful tool for beam-matching between the RTMs. Therefore a similar system was planned and constructed for the HDSM.

*A. Jankowiak et al. “Status Report on the Harmonics Double Sided Microtron of MAMI C”, this conference.

 
TUPCH118 Manufacturing and Testing of 2.45 GHz and 4.90 GHz Biperiodic Accelerating Structures for MAMI C 1292
 
  • A. Jankowiak, O. Chubarov, H. Euteneuer
    IKP, Mainz
  • K. Dunkel, C. Piel, H. Vogel, P. vom Stein
    ACCEL, Bergisch Gladbach
 
  At the Institut fur Kernphysik (IKPH) of Mainz University the fourth stage of the Mainz Microtron (MAMI), a 855MeV to 1500MeV Harmonic Double Sided Microtron*, is now on the verge of first operation. For this project ACCEL Instruments GmbH manufactured biperiodic, on axis coupled, standing wave accelerating structures at the frequencies of 2.45GHz and 4.90GHz. Four resp. eleven multicell sections were manufactured, low power characterized and after delivery tested at the high power test stand of IKPH. This paper describes the production and characterization of these structures, presents results of the high power tests, and compares these data with results gained at IKPH for an in house built 4.90GHz prototype and the 2.45GHz structures built in the 1980s.

*A. Jankowiak et al. "Design and Status of the 1.5 GeV-Harmonic Double Sided Microtron for MAMI", Proceedings EPAC2002, Paris, p. 1085.