A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Hoberg, H.G.

Paper Title Page
MOPCH148 First RF Tests in the HoBiCaT Superconducting Test Facility at BESSY 402
 
  • O. Kugeler, W. Anders, J. Borninkhof, H.G. Hoberg, S. Klauke, J. Knobloch, M. Martin, G. Mielczarek, A. Neumann, D. Pflückhahn, S. Rotterdam, M. Schuster, T. Westphal
    BESSY GmbH, Berlin
 
  In preparation for the construction of the BESSY-FEL User Facility, BESSY recently completed the installation of the HoBiCaT cryogenic test facility for superconducting RF (SRF) TESLA cavity units, including all ancillary devices (helium tank, input coupler, tuner, magnetic shielding). It is designed to house two such units in a configuration similar to that envisaged for the superconducting CW linac of the BESSY FEL. Commissioning of the facility is now complete and the first TTF-III RF coupler and cavity unit have been tested. In particular, the complete production, cleaning and assembly of the cavity unit was carried out by industry. These tests thus serve as a first step at qualifying industrial partners for series production of such systems, which will be essential for the future construction of SRF based light sources. Results will be presented.  
THPLS014 Status of the Metrology Light Source 3299
 
  • K. Buerkmann-Gehrlein, M. Abo-Bakr, W. Anders, P. Budz, O. Dressler, V. Duerr, J. Feikes, H.G. Hoberg, D. Krämer, P. Kuske, R. Lange, J. Rahn, T. Schneegans, D. Schueler, E. Weihreter, G. Wuestefeld
    BESSY GmbH, Berlin
  • R. Klein, G. Ulm
    PTB, Berlin
 
  For more than 25 years, the Physikalisch-Technische-Bundesanstalt (PTB) uses synchrotron radiation at the storage rings BESSY I and II for photon metrology in the spectral range of UV to x-rays. Since decommissioning of BESSY I (1999), there is a gap in the spectral range of UV and EUV wavelength due to the higher electron energy of BESSY II. Thus, in 2003, the Metrology Light Source (MLS), a low energy electron storage ring, was approved, as central instrument in the future Willy Wien Laboratory (WWL). Design, construction and operation of the MLS are realized by BESSY, based on the PTB requirements for a permanent accessible radiometry source, optimized for the spectral range between UV up to VUV. The MLS is tuneable in energy between 200 MeV and 600 MeV, designed for currents between 1pA up to 200mA. Civil construction of WWL in the close vicinity to BESSY is nearing completion. The first MLS components will be installed in spring 2006, commissioning of the 100MeV Microtron is scheduled for summer 2006, while commissioning of the storage ring will start in spring 2007. Regular user operation will begin in January 2008. A status and an overview on the construction of the MLS are