A   B   C   D   E   F   G   H   I   K   L   M   N   O   P   Q   R   S   T   U   V   W    

beam-cooling

Paper Title Other Keywords Page
MOPLT118 Muon Test Area at Fermilab linac, booster, instrumentation, factory 812
 
  • M. Popovic
    Fermilab, Batavia, Illinois
  A construction of a new experimental area designed to develop, test and verify muon ionization cooling using the 400- MeV Fermilab Linac proton beam was finished in fall of 2003. This area will be used initially for cryogenic tests of liquid-hydrogen absorbers for the MUCOOL R&D program and, later, for high-power beam tests of these absorbers and other prototype muon-cooling apparatus. The experimental scenarios being developed for muon facilities involve collection, capture, and cooling of large-emittance, high-intensity muon beams–~1013 muons at a repetition rate of 15Hz, so that conclusive tests of the apparatus require full Linac beam, or 1.6 x 1013 p at 15 Hz. The area has 12MW 805MHz, 5MW 201MHz RF, 4K Helium, 500W refrigeration and 400MeV H-/proton beam.