MOPF08 |
Secondary Electron Measurements at the HIM Electron Cooler Test Set-Up |
electron, simulation, dipole, optics |
48 |
|
- M.W. Bruker, K. Aulenbacher, J. Dietrich, A. Hofmann, T. Weilbach
HIM, Mainz, Germany
|
|
|
The planned advances in electron cooling technology aimed at improving the operation of future hadron storage rings include an increase in electron beam current and acceleration voltage. A test set-up has been built at Helmholtz-Insitut Mainz (HIM) to optimize the recuperation efficiency of such high-current beams in energy recovery operation, requiring a thorough understanding of their interaction with external electric and magnetic fields, such as those found in a Wien velocity filter. Beam diagnostics are carried out using a BPM and current-sensing scraper electrodes. At present, the set-up can be successfully operated at U=17 kV, I=600 mA, showing a relative secondary electron current of about 2·10-4. We present the current state of the project and its objectives for the foreseeable future.
|
|