Paper | Title | Page |
---|---|---|
MOXAUD01 |
Performance of the 2 MeV Electron Cooler at COSY | |
|
||
The 2 MeV electron cooler is operated in the COSY ring since 2013. So far electron beam energy up to 1.5 MeV was demonstrated. Dedicated electron cooling studies with proton beams up to 1.66 GeV kinetic energy and electron beam current up to 0.9 A were carried out. A reduction of proton beam emittance by one order of magnitude within a few hundred seconds was observed. Overview of HV and electron beam commissioning activities is presented. Electron cooling results are discussed. | ||
![]() |
Slides MOXAUD01 [4.097 MB] | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
MOXAUD02 | Experimental Observation of Longitudinal Electron Cooling of DC and Bunched Proton Beam at 2425 MeV/c at COSY | 10 |
|
||
The 2 MeV electron cooling system for COSY-Julich started operation in 2013 years. The cooling process was observed in the wide energy range of the electron beam from 100 keV to 908 keV. Vertical, horizontal and longitudinal cooling was tested at bunched and continuous beams. The cooler was operated with electron current up to 0.9 A. This report deals with the description of the experimental observation of longitudinal electron cooling of DC and bunched proton beam at 2425 MeV/c at COSY. | ||
![]() |
Slides MOXAUD02 [10.860 MB] | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |