Paper |
Title |
Page |
MOPB076 |
Horizontal RF Test of a Fully Equipped 3.9 GHz Cavity for the European XFEL in the DESY AMTF |
301 |
|
- C.G. Maiano, C. Albrecht, R. Bospflug, J. Branlard, Ł. Butkowski, T. Delfs, J. Eschke, A. Gössel, F. Hoffmann, M. Hüning, K. Jensch, R. Jonas, R. Klos, D. Kostin, W. Maschmann, A. Matheisen, U. Mavrič, W.-D. Möller, C. Müller, K. Mueller, B. Petersen, P. Pierini, J. Rothenburg, O. Sawlanski, M. Schmökel, A.A. Sulimov, E. Vogel
DESY, Hamburg, Germany
- A. Bosotti, M. Moretti, R. Paparella, P. Pierini, D. Sertore
INFN/LASA, Segrate (MI), Italy
- E.R. Harms
Fermilab, Batavia, Illinois, USA
- C.R. Montiel
ANL, Argonne, Illinois, USA
- S. Pivovarov
BINP SB RAS, Novosibirsk, Russia
|
|
|
In order to validate the cavity package concept before the module preparation for the European XFEL Injector, one 3.9 GHz cavity, complete with magnetic shielding, power coupler and frequency tuner was tested in a specially designed single cavity cryomodule in one of the caves of the DESY Accelerator Module Test Facility (AMTF). The cavity was tested in high power pulsed operation up to the quench limit of 24 MV/m, above the vertical test qualifications and all subsystems under test (coupler, tuner, waveguide tuners, LLRF system) were qualified to design performances.
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text,
※ RIS/RefMan,
※ EndNote (xml)
|
|
|
TUPB018 |
Preparation of the 3.9 GHz System for the European XFEL Injector Commissioning |
584 |
|
- P. Pierini, M. Bertucci, M. Bonezzi, A. Bosotti, J.F. Chen, M. Chiodini, P. Michelato, L. Monaco, M. Moretti, R. Paparella, D. Sertore
INFN/LASA, Segrate (MI), Italy
- C. Albrecht, N. Baboi, S. Barbanotti, J. Branlard, Th. Buettner, Ł. Butkowski, T. Delfs, H. Hintz, F. Hoffmann, M. Hüning, K. Jensch, R. Jonas, R. Klos, D. Kostin, L. Lilje, C.G. Maiano, W. Maschmann, A. Matheisen, U. Mavrič, W.-D. Möller, C. Müller, P. Pierini, J. Prenting, J. Rothenburg, O. Sawlanski, M. Schlösser, M. Schmökel, A.A. Sulimov, E. Vogel
DESY, Hamburg, Germany
- E.R. Harms
Fermilab, Batavia, Illinois, USA
- C.R. Montiel
ANL, Argonne, Illinois, USA
- C. Pagani
Università degli Studi di Milano & INFN, Segrate, Italy
|
|
|
The 3.9 GHz cryomodule and RF system for the XFEL Injector is being assembled and delivered to the underground building in summer 2015, for the injector commissioning in Fall 2015. This contribution outlines the status of the activity and reports the preparation stages of the technical commissioning of the system.
|
|
Export • |
reference for this paper to
※ BibTeX,
※ LaTeX,
※ Text,
※ RIS/RefMan,
※ EndNote (xml)
|
|
|
THPB035 |
Fabrication of the 3.9 GHz SRF Structures for the European XFEL |
1162 |
|
- P. Pierini, M. Bertucci, A. Bosotti, J.F. Chen, P. Michelato, L. Monaco, M. Moretti, R. Paparella, D. Sertore
INFN/LASA, Segrate (MI), Italy
- A. Gresele
Ettore Zanon S.p.A., Nuclear Division, Schio, Italy
- C.G. Maiano, P. Pierini, E. Vogel
DESY, Hamburg, Germany
- C. Pagani
Università degli Studi di Milano & INFN, Segrate, Italy
- M. Rizzi
Ettore Zanon S.p.A., Schio, Italy
|
|
|
One batch of 10 cavities has been completed and eight structures have been installed in the 3.9 GHz cryomodule for the European XFEL Injector operation. A second batch of 10 RF structures for a spare injector module is under fabrication. The fabrication has been performed according to the European Pressure Vessel regulations, as needed for the EXFEL operation. This paper describes the fabrication, quality control/assurance procedures and frequency preparation steps in order to achieve cavities at the correct frequency and length within the specifications.
|
|