Author: Jensch, K.
Paper Title Page
MOPO010 Update on Module Measurements for the XFEL Prototype Modules 65
 
  • D. Kostin, A. Gössel, K. Jensch, W.-D. Möller, A.A. Sulimov
    DESY, Hamburg, Germany
 
  The Cryo Module Test Bench (CMTB) at DESY is used since several years for the SRF module tests. Three XFEL prototypes modules, PXFEL1,2,3, were tested on this facility. An update on the SRF modules testing activities since PXFEL1 test is presented.  
poster icon Poster MOPO010 [0.288 MB]  
 
THIOA01 Test Results of the International S1-Global Cryomodule 615
 
  • Y. Yamamoto, M. Akemoto, S. Fukuda, K. Hara, H. Hayano, N. Higashi, E. Kako, H. Katagiri, Y. Kojima, Y. Kondo, T. Matsumoto, H. Matsushita, S. Michizono, T. Miura, H. Nakai, H. Nakajima, K. Nakanishi, S. Noguchi, N. Ohuchi, T. Saeki, M. Satoh, T. Shidara, T. Shishido, T. Takenaka, A. Terashima, N. Toge, K. Tsuchiya, K. Watanabe, S. Yamaguchi, A. Yamamoto, K. Yokoya, M. Yoshida
    KEK, Ibaraki, Japan
  • C. Adolphsen, C.D. Nantista
    SLAC, Menlo Park, California, USA
  • T.T. Arkan, S. Barbanotti, M.A. Battistoni, H. Carter, M.S. Champion, A. Hocker, R.D. Kephart, J.S. Kerby, D.V. Mitchell, T.J. Peterson, Y.M. Pischalnikov, M.C. Ross, W. Schappert, B.E. Smith
    Fermilab, Batavia, USA
  • A. Bosotti, C. Pagani, R. Paparella, P. Pierini
    INFN/LASA, Segrate (MI), Italy
  • K. Jensch, D. Kostin, L. Lilje, A. Matheisen, W.-D. Möller, P. Schilling, M. Schmökel, N.J. Walker, H. Weise
    DESY, Hamburg, Germany
 
  S1-Global collaborative project by joint efforts of INFN, DESY, FNAL, SLAC and KEK, finished successfully at KEK- STF on February in 2011, is a crucial project for ILC. For this project, 8 SRF cavities, 2 from DESY, 2 from FNAL and 4 from KEK, were installed into one cryomodule with the thermal shields and the cooling pipes of liquid helium and nitrogen, cooled down to 2K totally three times, and cold-tested by using the three different frequency tuning systems (Blade tuner from INFN/FNAL, Saclay tuner from DESY and Slide-Jack tuner from KEK) and two types of input couplers (TTF III from DESY and STF#2 from KEK). During the cold test with high power, cavity performance, LFD (Lorentz Force Detuning) compensation by Piezo actuator, simultaneous 7 SRF cavities operation, dynamic heating loss measurement including static loss and DRFS (Distributed RF Scheme) operation with LLRF (Low Level RF) feedback system, were established successfully. In this talk, the results of the S1-Global cryomodule test are reported, discussed and summarized.  
slides icon Slides THIOA01 [11.254 MB]