Author: Barbanotti, S.
Paper Title Page
MOPO024 Design of Single Spoke Resonators for Project X 122
 
  • L. Ristori, S. Barbanotti, P. Berrutti, M.S. Champion, M.H. Foley, C.M. Ginsburg, I.G. Gonin, C.J. Grimm, T.N. Khabiboulline, D. Passarelli, N. Solyak, A. Vostrikov, V.P. Yakovlev
    Fermilab, Batavia, USA
 
  Funding: Operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the U.S. Department of Energy.
Project X is based on a 3 GeV CW superconducting linac and is currently in the R&D phase awaiting CD-0 approval. The low-energy section of the Project X H linac (starting at 2.5 MeV) includes three types of super-conducting single spoke cavities operating at 325 MHz. The first three cryomodules will each house 7 SSR0 cavities at β = 0.11. The following two cryomodules will each contain 10 SSR1 cavities each at β = 0.21. The last four cryomodules will contain 11 SSR2 cavities each at β = 0.4. Single spoke cavities were selected for the linac in virtue of their higher r/Q values compared to standard Half Wave Resonator. Quarter Wave Resonators were not considered for such a high frequency. In this paper we present the decisions and analyses that lead to the final design of SSR0. Electro-magnetic and mechanical finite element analyses were performed with the purpose of optimizing the electro-magnetic design, minimizing frequency shifts due to helium bath pressure fluctuations and providing a pressure rating for the resonators that allow their use in the cryomodules.
 
 
TUPO001 Development of Quality Assurance Procedures for the Fast/Slow Tuners on the 1.3 GHz SRF Cavities for the SRF Accelerator Test Facility at Fermilab 344
 
  • Y.M. Pischalnikov, S. Barbanotti, C.J. Grimm, T.N. Khabiboulline, R.V. Pilipenko, W. Schappert
    Fermilab, Batavia, USA
 
  The 1.3 GHz elliptical SRF cavities being prepared for cryomodules of the Fermilab SRF Accelerator Test Facility are equipped with coaxial blade tuners. Quality Assurance tests of these tuners during initial installation, cold testing in the Horizontal Test Stand and during string assembly are described.  
poster icon Poster TUPO001 [1.811 MB]  
 
THIOA01 Test Results of the International S1-Global Cryomodule 615
 
  • Y. Yamamoto, M. Akemoto, S. Fukuda, K. Hara, H. Hayano, N. Higashi, E. Kako, H. Katagiri, Y. Kojima, Y. Kondo, T. Matsumoto, H. Matsushita, S. Michizono, T. Miura, H. Nakai, H. Nakajima, K. Nakanishi, S. Noguchi, N. Ohuchi, T. Saeki, M. Satoh, T. Shidara, T. Shishido, T. Takenaka, A. Terashima, N. Toge, K. Tsuchiya, K. Watanabe, S. Yamaguchi, A. Yamamoto, K. Yokoya, M. Yoshida
    KEK, Ibaraki, Japan
  • C. Adolphsen, C.D. Nantista
    SLAC, Menlo Park, California, USA
  • T.T. Arkan, S. Barbanotti, M.A. Battistoni, H. Carter, M.S. Champion, A. Hocker, R.D. Kephart, J.S. Kerby, D.V. Mitchell, T.J. Peterson, Y.M. Pischalnikov, M.C. Ross, W. Schappert, B.E. Smith
    Fermilab, Batavia, USA
  • A. Bosotti, C. Pagani, R. Paparella, P. Pierini
    INFN/LASA, Segrate (MI), Italy
  • K. Jensch, D. Kostin, L. Lilje, A. Matheisen, W.-D. Möller, P. Schilling, M. Schmökel, N.J. Walker, H. Weise
    DESY, Hamburg, Germany
 
  S1-Global collaborative project by joint efforts of INFN, DESY, FNAL, SLAC and KEK, finished successfully at KEK- STF on February in 2011, is a crucial project for ILC. For this project, 8 SRF cavities, 2 from DESY, 2 from FNAL and 4 from KEK, were installed into one cryomodule with the thermal shields and the cooling pipes of liquid helium and nitrogen, cooled down to 2K totally three times, and cold-tested by using the three different frequency tuning systems (Blade tuner from INFN/FNAL, Saclay tuner from DESY and Slide-Jack tuner from KEK) and two types of input couplers (TTF III from DESY and STF#2 from KEK). During the cold test with high power, cavity performance, LFD (Lorentz Force Detuning) compensation by Piezo actuator, simultaneous 7 SRF cavities operation, dynamic heating loss measurement including static loss and DRFS (Distributed RF Scheme) operation with LLRF (Low Level RF) feedback system, were established successfully. In this talk, the results of the S1-Global cryomodule test are reported, discussed and summarized.  
slides icon Slides THIOA01 [11.254 MB]