Author: Huang, J.Y.
Paper Title Page
MOP179 Numerical Study on Zone Plate Imaging 423
 
  • I.S. Ko
    POSTECH, Pohang, Kyungbuk, Republic of Korea
  • J.Y. Huang, Y.W. Parc
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Funding: This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Ministry of Education, Science and Technology (MEST) (grant No. R0A-2008-000-20013-0).
The X-ray is focused by two zone plates in 1B2 beamline to image electron beam in PLS. From numerical study, we can determine the optical limit of resolution with the same specifications of Fresnel zone plates in 1B2 beamline. The width of Airy pattern and the outmost width of zone plates are turned out to be not good parameters to determine the resolution of the imaging system with a zone plate. The resolution of the entire imaging system 1B2 beamline will be revealed as 682 nm.