Author: Huang, G.
Paper Title Page
WEOBS5 Status of the Short-Pulse X-ray Project (SPX) at the Advanced Photon Source (APS) 1427
 
  • R. Nassiri, N.D. Arnold, G. Berenc, M. Borland, D.J. Bromberek, Y.-C. Chae, G. Decker, L. Emery, J.D. Fuerst, A.E. Grelick, D. Horan, F. Lenkszus, R.M. Lill, V. Sajaev, T.L. Smith, G.J. Waldschmidt, G. Wu, B.X. Yang, A. Zholents
    ANL, Argonne, USA
  • J.M. Byrd, L.R. Doolittle, G. Huang
    LBNL, Berkeley, California, USA
  • G. Cheng, G. Ciovati, J. Henry, P. Kneisel, J.D. Mammosser, R.A. Rimmer, L. Turlington, H. Wang
    JLAB, Newport News, Virginia, USA
 
  Funding: Work at Argonne is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11354.
The Advanced Photon Source Upgrade project (APS-U) at Argonne includes implementation of Zholents’* deflecting cavity scheme for production of short x-ray pulses. This is a joint project between Argonne National Laboratory, Thomas Jefferson National Laboratory, and Lawrence Berkeley National Laboratory. This paper describes performance characteristics of the proposed source and technical issues related to its realization. Ensuring stable APS storage ring operation requires reducing quality factors of these modes by many orders of magnitude. These challenges reduce to those of the design of a single-cell SC cavity that can achieve the desired operating deflecting fields while providing needed damping of all these modes. The project team is currently prototyping and testing several promising designs for single-cell cavities with the goal of deciding on a winning design in the near future.
*A. Zholents et al., NIM A 425, 385 (1999).
 
slides icon Slides WEOBS5 [1.730 MB]  
 
MOP279 Synchronize Lasers to LCLS e- Beam 636
 
  • G. Huang
    TUB, Beijing, People's Republic of China
  • J.M. Byrd, L.R. Doolittle, R.B. Wilcox
    LBNL, Berkeley, California, USA
 
  Fiber based synchronization system is used in LCLS to synchronize the laser for pump probe experiment to average electron beam arrival time. Electron bunch arrival time measured by phase cavity is one of the best measurement for FEL X pulse until now. The average bunch arrival time is transmitted through electronic length stabilized fiber link to AMO and other experiment hall. The laser oscillator is phase locked to this reference signal to maintain low jitter and drift between pump and probe. The in loop error shows the jitter is less then 100 fs and meets the experiment requirement.