Author: Emma, P.
Paper Title Page
THP168 FEL Beam Stability in the LCLS* 2423
 
  • J.L. Turner, R. Akre, A. Brachmann, F.-J. Decker, Y.T. Ding, P. Emma, Y. Feng, A.S. Fisher, J.C. Frisch, A. Gilevich, P. Hering, K. Horovitz, Z. Huang, R.H. Iverson, D. Kharakh, A. Krasnykh, J. Krzywinski, H. Loos, M. Messerschmidt, S.P. Moeller, H.-D. Nuhn, D.F. Ratner, T.J. Smith, J.J. Welch, J. Wu
    SLAC, Menlo Park, California, USA
 
  Funding: *This work was supported by U.S. Department of Energy, Office of Basic Energy Sciences, under Contract DE-AC02-76SF00515
During commissioning and operation of the Linac Coherent Light Source (LCLS) x-ray Free Electron Laser (FEL) at the SLAC National Accelerator Center electron and x-ray beam size, shape, centroid motion have been studied. The studies, sources, and remediation are summarized in this paper.
 
 
THP183 Measurement of Femtosecond LCLS Bunches Using the SLAC A-line Spectrometer* 2459
 
  • Z. Huang, A. Baker, M. Boyes, J. Craft, F.-J. Decker, Y.T. Ding, P. Emma, J.C. Frisch, R.H. Iverson, J.J. Lipari, H. Loos, D.R. Walz
    SLAC, Menlo Park, California, USA
  • C. Behrens
    DESY, Hamburg, Germany
 
  We describe a novel technique and the preliminary experimental results to measure the ultrashort bunch length produced by the LCLS low-charge, highly compressed electron bunch. The technique involves adjusting the LCLS second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final 550-m of linac. As a result, the time coordinate of the bunch is directly mapped onto the energy coordinate at the end of the linac. A high-resolution energy spectrometer located at an existing transport line (A-line) is then commissioned to image the energy profile of the bunch in order to retrieve its temporal information. We present measurements of the single-digit femtosecond LCLS bunch length using the A-line as a spectrometer and compare the results with the transverse cavity measurement as well as numerical simulations.  
 
THP184 Tuning of the LCLS Linac for User Operation 2462
 
  • H. Loos, R. Akre, A. Brachmann, F.-J. Decker, Y.T. Ding, P. Emma, A.S. Fisher, J.C. Frisch, A. Gilevich, P. Hering, Z. Huang, R.H. Iverson, N. Lipkowitz, H.-D. Nuhn, D.F. Ratner, J.A. Rzepiela, T.J. Smith, J.L. Turner, J.J. Welch, W.E. White, J. Wu, G. Yocky
    SLAC, Menlo Park, California, USA
 
  Funding: This work was supported by U.S. Department of Energy, Office of Basic Energy Sciences, under Contract DE-AC02-76SF00515.
With the Linac Coherent Light Source (LCLS) now in its third user run, reliable electron beam delivery at various beam energies and charge levels has become of high operational importance. In order to reduce the beam tuning time required for such changes, several diagnostics and feed-forward procedures have been implemented. We report on improved lattice diagnostics to detect magnet, model, and diagnostics errors as well as on measurements of transverse RF kicks and static field contributions and corresponding correction procedures to facilitate beam energy changes.