Author: Avrakhov, P.V.
Paper Title Page
TUP066 Three-cell Traveling-wave Superconducting Test Structure 940
 
  • P.V. Avrakhov, A. Kanareykin
    Euclid TechLabs, LLC, Solon, Ohio, USA
  • S. Kazakov, N. Solyak, G. Wu, V.P. Yakovlev
    Fermilab, Batavia, USA
 
  Use of a superconducting traveling wave accelerating (STWA) structure* with a small phase advance per cell rather than a standing wave structure may provide a significant increase of the accelerating gradient in the ILC linac. For the same surface electric and magnetic fields the STWA achieves an accelerating gradient 1.2 larger than TESLA-like standing wave cavities. The STWA allows also longer acceleration cavities, reducing the number of gaps between them. However, the STWA structure requires a SC feedback waveguide to return the few hundreds of MW of circulating RF power from the structure output to the structure input. A test single-cell cavity with feedback was designed, manufactured and successfully tested** demonstrating the possibility of a proper processing to achieve a high accelerating gradient. These results open the way to take the next step of the TW SC cavity development: to build and test a traveling-wave three-cell cavity with a feedback waveguide. The latest results of the single-cell cavity tests are discussed as well as the design of the test 3-cell TW cavity.
* P. Avrakhov, et al, Phys. of Part. and Nucl. Let, 2008, Vol. 5, No. 7, p. 597
** G. Wu, et al, IPAC 2010, THPD048