TUP008 Recent Changes to the e- / e+ Injector (Linac II) at DESY 401
 
  • M. Hüning, M. Schmitz
    DESY, Hamburg
 
 

The Linac II at DESY consists of a 6A/150kV DC electron gun, a 400 MeV primary electron linac, a 800 MW positron converter, and a 450 MeV secondary electron/positron linac. The Particle Intensity Accumulator (PIA) is also considered part of the injector complex accumulating and damping the 50 Hz beam pulses from the linac and transferring them with a rate of 6.25 Hz or 3.125 Hz into the Synchrotron DESY II. The typical positrons rates are 6·1010/s. DESY II and Linac II will serve as injectors for the two synchrotron light facilities PETRA III and DORIS. Since PETRA III will operate in top-up mode, Linac availability of 98-99% are required. DORIS requires positrons for operation. Therefore during top-up mode positrons are required for both rings. In order to maintain its reliability over the operation time of the new facility PETRA III, the major components of the linac were renovated. Some components were redesigned taking into account experience from 30 years of operation.